|
The UKHA-ARCHIVE IS CEASING OPERATIONS 31 DEC 2024
|
|
[Date Prev][Date
Next][Thread Prev][Thread Next][Date
Index][Thread Index]
Re: More LD10/11 Questions
> Are you doing this with your HV or COmfort...
It's a bit round-a-bout Richard but it works really well. The PIRs are
attached to Comfort. The new UMC passes the info that the PIR has fired to
ACE. ACE then sends a command via DDE to HomeVision to run a macro. The
macro is very simple. Here's the one for the Hall Lights...
If
Flag #1 (Dark) is set
Then
If
Timer #13 (Downstairs Hall Movement) is running
Then
Load timer #13 (Downstairs Hall Movement) with 0:00:20.00 and start
Else
X-10: A 1 (Hall Halogens) Force Brighten 8 Times
Load timer #13 (Downstairs Hall Movement) with 0:00:20.00 and start
End If
End If
As you can see I never actually send an "ON" command.
The timer then looks like this...
X-10: A 1 (Hall Halogens) Force Dim 8 Times
X-10: A 1 (Hall Halogens) Force Off
> I'm curious how your turning them off and then back on at
> 0%...Everytime I've tried the on action hv brings it on at full
Are you using LD10s or plug in modules Richard?
> Are you taking that at 0% its off or are you actually sending the off
> command?
I dim back down then send an off as above.
M.
--------------------------------------------------------------------<e-
Click for more information on how eGroups members save with beMANY!
http://click.egroups.com/1/6780/9/_/2065/_/965830276/
--------------------------------------------------------------------e>-
Home |
Main Index |
Thread Index
|
|