Thanks for the responses so far...

So I am scrapping the dimmers possibly - need to do a bit more research on
this.

10002	LD10 DIN Mounted Lamp Module (LD11 Internal Software)
=A334.99 * 14
10455	DIN Enclosure for 1 x LD10/LD11
=A317.63 * 14
10 * 1 gang faceplates
3 * 2 gang faceplates

and replacing them with something like:

10030	APPLIANCE SWITCH AW10U (Requires NEUTRAL Wire)	=A330

however my switches are unlikely to have a neutral wire ??? and also some
likes the stairs/landing switches are 2 gang ???
Which the AW10U isn't ? And I'd like a brass coloured switches.=20


Also as I am going for HomeVision I don't need the IR7243AH. Correct ?

Do I need the XM10U ?

And then add 2* the number of cat5 lines/ports.

and finally some IR repeaters when Ian has finished them :-)

and probably not bother with the WS10's either.

thanks so far

alex

>=20
>=20
> > flooring down and fit LV lighting,
>=20
> LV lighting does not mix well with X10 dimming. Basically the=20
> transformers
> don't like it and may fail, catch fire if you try it. They=20
> are fine with
> appliance type modules as these are straight on/off. Mains=20
> voltage halogens
> are fine for dimming.
>=20
> > In essence I am looking to have a small internal network=20
> 1-2 data ports in
> > each room, and then be able to connect=20
> tv/satellite/dvd/video around the
>=20
> Fit more CAT5 cable and ports and then double it. Pretty much=20
> everything can
> run over CAT5 including all you telly requirements - see Kat5=20
> from Keith
> Doxey.
>=20
> > 95000	Pronto RU890 Remote & RU941 Docking Station=20
> (Package Price)
> > =A3179.95
> > 10512	IR7243AH All House Code IR->X10 Converter for=20
> Pronto/RC5000
> > =A372.85
> > 10215	XM10U (TW7223) X10 -> Mains Interface
> > =A330
>=20
> All good choices
>=20
> > 10003	HomeVision Home Automation Controller 3.0 PAL=09
> 		=A3440
>=20
> Go for the standalone unit. It is small and under normal=20
> circumstances one
> of the most reliable bits of kit you can buy today. Budget=20
> for an expansion
> board in the future as that is great as well. Temperature=20
> input via Dallas
> thingies (1820s) and the analogue port etc.
>=20
> > Then, in terms of the house I am looking at fitting low=20
> voltage lighting
> > throughout which means:
> >
> > Room		Dimmers	Data Ports/TV-AV Ports
> > Lounge		2 gang		2/2
> > Dining Room	1		2/1
> > Hallway		2 gang		2/1
> > CloakRoom	1
> > Kitchen		1		2/1
> > FamilyRoom	1		2/1
> >
> > Bedroom1	1		2/2
> > Bedroom2	1		2/1
> > Bedroom3	1		2/1
> > Bedroom4	1		2/1
> > Bathroom	1
> > Ensuite		1
> > Landing		2 gang		2/1
> >
> > Does this therefore mean that I need 14 of the following for the
> > Low Voltage
> > Lighting?
> >
> > 10002	LD10 DIN Mounted Lamp Module (LD11 Internal Software)
> > =A334.99 * 14
> > 10455	DIN Enclosure for 1 x LD10/LD11
> > =A317.63 * 14
> > 10 * 1 gang faceplates
> > 3 * 2 gang faceplates
> >
> > Is there a cheaper source for brass faceplate dimmers as=20
> 10070/1 is > =A370
> > each ?
> >
> > In order to do the Data Ports/TV-AV ports I am guessing I need
> > around 2.5km
> > of cat5e wiring ? Does that sound correct.
> > Also where is a good place to purchase this (I live near
Windsor)?
> >
> > I also presume I will need to grab some Kat5 widget thingies so I
> > can run AV
> > over the cat5e? Is that the generally recommended way now ?
> >
>=20
> See notes at the beginning!!!
>=20
> > Ok also needed will be:
> >
> > crimping tool - yes
> > IR detector - any suggestions which one ? detector??
> > patch panel - any suggestions which one ? - lets automate=20
> ones are a good
> price although I have never seen one in the flesh.
> > patch panel leads - yes
> > and then a mixture of AM12/LM12/AW10 for the mains electrics. -
yes
> > Whats people's view on the WS10, its much more expensive so=20
> is it worth it
> ? - pass
>=20
> > Anything else I missed, any other recomendations?
>=20
> You may want to think about IR distribution. I am developing=20
> some PIC based
> IR repeaters and Keith is working on IR return for KAT5. Mine=20
> will need
> about 5 lines in a CAT5 cable between A and B.
>=20
> Ian
>=20
>=20
> For more information: http://www.automatedhome.co.uk=20
> Post message: ukha_d@xxxxxxx=20
> Subscribe:  ukha_d-subscribe@xxxxxxx=20
> Unsubscribe:  ukha_d-unsubscribe@xxxxxxx=20
> List owner:  ukha_d-owner@xxxxxxx=20
>=20
> Your use of Yahoo! Groups is subject to=20
http://docs.yahoo.com/info/terms/=20


For more information: http://www.automatedhome.co.uk=20
Post message: ukha_d@xxxxxxx=20
Subscribe:  ukha_d-subscribe@xxxxxxx=20
Unsubscribe:  ukha_d-unsubscribe@xxxxxxx=20
List owner:  ukha_d-owner@xxxxxxx=20

Your use of Yahoo! Groups is subject to http://docs.yahoo.com/info/terms/=20




Home | Main Index | Thread Index

Comments to the Webmaster are always welcomed, please use this contact form . Note that as this site is a mailing list archive, the Webmaster has no control over the contents of the messages. Comments about message content should be directed to the relevant mailing list.