[Date Prev][Date
Next][Thread Prev][Thread Next][Date
Index][Thread Index]
RE: 2 Way
- To: <ukha_d@xxxxxxx>
- Subject: RE: 2 Way
- From: "Paul Miller" <pmiller@xxxxxxx>
- Date: Fri, 16 Feb 2001 21:36:23 -0000
- Delivered-to: rich@xxxxxxx
- Delivered-to: mailing list ukha_d@xxxxxxx
- Mailing-list: list ukha_d@xxxxxxx; contact
ukha_d-owner@xxxxxxx
- Reply-to: ukha_d@xxxxxxx
only the US modules that advertise themselves as supporting status request,
this means that you can poll a device to confirm that what HV believes the
condition of the device is actual correct.
-----Original Message-----
From: Nigel friery [mailto:nigel@xxxxxxx]
Sent: 16 February 2001 21:48
To: ukha_d@xxxxxxx
Subject: RE: [ukha_d] 2 Way
Yes much.
Thats really frustrating you can't receive from appliance and light
modules.
So because HV has the functionality built in to receive - I assume the US
appliance & light modules do send to HV.
I'm going for a drink now, I've learnt something
Thanks for your explanation and help
Nigel
-----Original Message-----
From: Paul Miller [mailto:pmiller@xxxxxxx]
Sent: 16 February 2001 21:05
To: ukha_d@xxxxxxx
Subject: RE: [ukha_d] 2 Way
1) correct
2) & 3) I think you may be getting confused because there is a company
called x10 as well as the protocol x10 (how the device talk to each other
across the mains). forgetting about the company, not all devices can send
and receive commands; e.g for UK models
UNIT Send Receive
Appliance modules N Y
Light Modules N Y
Light Switches N Y
Motion Detectors Y N
Maxi Controllers Y N
Mini Controllers Y N
Is that any clearer?
Paul
-----Original Message-----
From: Nigel friery [mailto:nigel@xxxxxxx]
Sent: 16 February 2001 20:53
To: ukha_d@xxxxxxx
Subject: RE: [ukha_d] 2 Way
Thanks but a little confused
If I read it right
1) HV has the functionality to cope.
2) In Uk non "X10 manufactured" units can send a X10 command.
3) But X10 "manufactured" units cannot.
If I am correct where can I purchase controllers such as light switches
which do work ?
Thanks
Nigel
-----Original Message-----
From: Paul Miller [mailto:pmiller@xxxxxxx]
Sent: 16 February 2001 20:20
To: ukha_d@xxxxxxx
Subject: RE: [ukha_d] 2 Way
HV will listen for other devices sending a X10 command and then alter the
X10 status within HV to reflect the change.
BUT, in the UK only other controllers or motion detectors, keypads etc can
SEND a X10 command the standard units such as appliance modules, light
modules and light switches cannot send X10 commands hence they cannot show
they have been switched on by a local control.
-----Original Message-----
From: Nigel friery [mailto:nigel@xxxxxxx]
Sent: 16 February 2001 20:28
To: UKHA
Subject: [ukha_d] 2 Way
Does anyone know,
In a UK setup using Homevision and X10 units.
The Homevision spec states it "monitors" the X10 units for their
state
(on/off etc).
Is this still true for the UK spec X10 units.
Thanks
nigel
Home |
Main Index |
Thread Index
|