buzz buzz bloody buzz :(


  • To: "'ukha_d@xxxxxxx'" <ukha_d@xxxxxxx>
  • Subject: buzz buzz bloody buzz :(
  • From: "BUTLER, Tony, FM" <tony.butler@xxxxxxx>
  • Date: Mon, 22 Apr 2002 11:37:48 +0100
  • Delivered-to: ukha_archive@xxxxxxx
  • Delivered-to: mailing list ukha_d@xxxxxxx
  • Mailing-list: list ukha_d@xxxxxxx; contact ukha_d-owner@xxxxxxx
  • Reply-to: ukha_d@xxxxxxx

Continuing on from last weeks exploits,  as I now had a buzzing site transformer, a 110v strip block & what was a buzzing 110v amp, I decided to hook them all together to see if the amp buzzed with this transformer like it did with the autotransformer I used before - though I still don't know why an autotransformer would cause buzzing in the first place :(
 
First though, lid off the site transformer to see if I can tighten the windings as Keith suggested.....nope, darned thing is fixed in place with some sort of resin, filling up 1/2 the box  - presumably to reduce the buzzing :(
 
Okay, swap the plug on the 110v strip for the ugly (but safe!) one I bought with the xformer and.... hey presto - it all works!
The amp doesn't buzz either.  Result!
Hooked up my audiotron to it & it works quite happliy for 1/2 hr, maybe 3/4 hr & then stops.
5A fuse in the amp is blown ......
 
hmmm, okay lets replace it..... Bugger - it's longer than a normal one.
So out with my trusty 5A fuse wire (last seen replacing the 100mA fuse that kept blowing in the AudioTron coz I didn't have a 125mA one!) solder it to the old fuse and connect up again.....
And the fuse blew a second time :(((((
 
What's up with this damned thing?????  I dunno.
Was happily playing music, didn't change the volume or anything & it's dead now :(
 
Anyone any thoughts on this?
The only thing I can think is maybe I wired the plug up incorrectly-  green E, white L, black N?  
I dunno what to do now - I don't want to bung in a higher rated fuse in case I damage it further.
Could it be the xformer putting out too high a voltage?
 
Maybe I will need to take the amp to a pro (as the only pro I know is in Eire), in which case, does anyone know a repair man in/around Croydon who wouldn't be afraid to touch a 110v amp and, importantly, who wouldn't charge a fortune for the privilege?
 
 
cheers chaps,
 
 
(jinxed) Tony


********************************************************************
Visit our Internet site at http://www.rbsmarkets.com

This e-mail is intended only for the addressee named above.
As this e-mail may contain confidential or privileged information,
if you are not the named addressee, you are not authorised to
retain, read, copy or disseminate this message or any part of it.
********************************************************************

Yahoo! Groups Sponsor
ADVERTISEMENT
Click Here!

For more information: http://www.automatedhome.co.uk
Post message: ukha_d@xxxxxxx
Subscribe:  ukha_d-subscribe@xxxxxxx
Unsubscribe:  ukha_d-unsubscribe@xxxxxxx
List owner:  ukha_d-owner@xxxxxxx

Your use of Yahoo! Groups is subject to the Yahoo! Terms of Service.

Home | Main Index | Thread Index

Comments to the Webmaster are always welcomed, please use this contact form . Note that as this site is a mailing list archive, the Webmaster has no control over the contents of the messages. Comments about message content should be directed to the relevant mailing list.