Thanks Jon. My electrician wired one up at the light switch and
another at the ceiling light to see if it made any difference. She
says I have a neutral at the light switch so it shouldn't make any
difference. Both methods produced the same results, but even when the
2nd switch didn't turn the light on it sent an X10 code! I thought
that was really strange. Why would it send an X10 code but not turn
the light on/off?

I'll show her your diagram and see what she makes of it. Yes - she!
The male electricians I asked to help didn't want to know or they
were totally baffled by it! I'm not omplaoning! ;-)

Gary


--- In ukha_d@y..., "Jon Whiten" <jon@w...> wrote:
> How are the switches wired up to the AWM2?
>
> If you have two standard on-off switches in parallel then this will
not work
> as effectively the module can sense nothing when one of the
switches is in
> the on position.  The answer is to move to momentary switches.
>
> Should your switches be wired up as standard two-way units then I
would
> expect everything to be fine.
>
> If I understand these modules correctly and the module is at the
light
> fitting....
>
> L to Live Supply
> N To neutral supply
> Lamp Between Neutral and Switched output.
>
> Then... connect the existing two-way switch circuit across the blue
and
> brown wires
>
>
>           /o-----------o
> Brown ----               ---- Blue
>            o-----------o/
>        Switch A     Switch B
>
> +--------+
>        L---------- Live Supply
>        S----+
> AWM2       Lamp
>        N----+
>        N---------- Neutral Supply
> +--------+
>
> This is how I plan to connect one of these to my landing light
circuit.
>
>
> I think this is right but take no responsibility should there be
errors in
> the above.
>
> Regards,
>
> Jon
> http://www.whiten.co.uk/
>
>
>
> > -----Original Message-----
> > From: garygfx [mailto:garygfx@d...]
> > Sent: 01 August 2002 14:53
> > To: ukha_d@xxxxxxx > > Subject: [ukha_d] AWM2 2-way wiring problem
> >
> >
> > An electician has just wired up an AWM2 X10 module to a light
which
> > has switches to control it, but the 2nd switch only works when the
> > first switch is in a certain position. The X10 control works fine,
> > it's just the 2-way we have probs with.
> >
> > We've tried 2 ways of wiring it and neither work. We have ordinary
> > toggle switches, not momentary.
> >
> > TIA
> > Gary.
> >
> >


Yahoo! Groups Sponsor
ADVERTISEMENT

For more information: http://www.automatedhome.co.uk
Post message: ukha_d@xxxxxxx
Subscribe:  ukha_d-subscribe@xxxxxxx
Unsubscribe:  ukha_d-unsubscribe@xxxxxxx
List owner:  ukha_d-owner@xxxxxxx

Your use of Yahoo! Groups is subject to the Yahoo! Terms of Service.

Home | Main Index | Thread Index

Comments to the Webmaster are always welcomed, please use this contact form . Note that as this site is a mailing list archive, the Webmaster has no control over the contents of the messages. Comments about message content should be directed to the relevant mailing list.