The UK Home Automation Archive

Archive Home
Group Home
Search Archive


Advanced Search

The UKHA-ARCHIVE IS CEASING OPERATIONS 31 DEC 2024


[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

RE: RCS TX15-B Thermostat


  • To: <ukha_d@xxxxxxx>
  • Subject: RE: RCS TX15-B Thermostat
  • From: "Kevin Hawkins" <lists@xxxxxxx>
  • Date: Fri, 28 Jun 2002 17:41:57 +0100
  • Mailing-list: list ukha_d@xxxxxxx; contact ukha_d-owner@xxxxxxx
  • Reply-to: ukha_d@xxxxxxx

      Just one other question Peter - what is the interface that Homeseer
is using to receive and transmit X10 info ??

      Kevin

>  -----Original Message-----
> From:       Kevin Hawkins [mailto:lists@xxxxxxx]
> Sent:      28 June 2002 17:01
> To:      ukha_d@xxxxxxx > Subject:      RE: [ukha_d] RCS TX15-B Thermostat
>
>       Peter - the European versions of the TW523 (aka PSC-05) were called
> TW7223's and were later superseded by the XM10's. Theses XM10's send data
> slightly differently to the original 523's (some data is sent twice). The
> TW7223 would probably suffice. Let's Automate or Laser are likely sources
> although these 'obsolete' versions may not be listed online. HomeVision
> didn't work with the new XM10's correctly without a ROM upgrade.
>
>       BUT I notice you are trying to get hold of the 253's (sic) but
> Kenneth in his post below said that his problem went away when he moved
> from the 253 to an XM10 which is contrary to your experience so I think a
> little more research may be needed into the problem.
>
>       I had a TX15-B here but I am not using it currently, in fact I
> haven't seen it for a while (have just moved house). At that time I used
> it with a TW7223 without I believe any problems. I'll have a rummage and
> see if I can find it and try it with both interfaces. If I remember
> rightly there are some dip switches that set the format in which the
> thermostat sends its status information using extended X10 - is it
> possible that these are set incorrectly ??
>
>       Kevin
>
>       -----Original Message-----
>       From:       Peter Tuckett [mailto:ptuckett@xxxxxxx]
>       Sent:      28 June 2002 16:34
>       To:      ukha_d@xxxxxxx >       Subject:      RE: [ukha_d] RCS TX15-B Thermostat
>
>       Have tried to find a TW253 interface - any suggestions for
> stockists.
>
>                   -----Original Message-----
>                   From:       Peter Tuckett [mailto:ptuckett@xxxxxxx]
>
>                   Sent:      28 June 2002 15:18
>                   To:      ukha_d@xxxxxxx >                   Subject:      RE: [ukha_d] RCS TX15-B Thermostat
>
>                   Thanks Keith. I’ll give that a try
>
>                   Pete
>
>                   -----Original Message-----
>                   From:       Kenneth Watt
> [mailto:kennwatt@xxxxxxx]
>                   Sent:      28 June 2002 12:18
>                   To:      ukha_d@xxxxxxx >                   Subject:      RE: [ukha_d] RCS TX15-B Thermostat
>
>                   I had the same problem and changing to the XM10 from
> a TW253 cured the problem for me, the only other thing could be
> interference really or a problem at the PC end.
>
>                   K.
>
>                   -----Original Message-----
>                   From: Peter Tuckett [mailto:ptuckett@xxxxxxx]
>                   Sent: 28 June 2002 11:57
>                   To: ukha_d@xxxxxxx >                   Subject: [ukha_d] RCS TX15-B Thermostat
>
>                   I have a problem setting up TX15-B, using xm10e-120,
> with homeseer. Commands are accepted ok but I am unable to get any status
> information.
>
>                   I have checked the interface cable and changed the
> xm10 with no effect
>
>                   Can anyone help
>
>                   Thanks
>
>                   Pete

For more information: http://www.automatedhome.co.uk
Post message: ukha_d@xxxxxxx
Subscribe:  ukha_d-subscribe@xxxxxxx
Unsubscribe:  ukha_d-unsubscribe@xxxxxxx
List owner:  ukha_d-owner@xxxxxxx

Your use of Yahoo! Groups is subject to the Yahoo! Terms of Service.