http://www.texe.com/index2.asp?pagename=english/products/veritas_series.html
Veritas R8 - using the Reflex PIRs they make too.
G.
Gareth Cook
SWG EMEA North Account Manager
IBM SWG - BTE Office - Lotus Park, Staines, TW18 3AG
Office: +44 (0)1784 445166 - Mobile: +44 (0)7980 445166
AIM Chat : TheBoyG - MSN Chat : chat@xxxxxxx
email: g@xxxxxxx
----- Forwarded by Gareth Cook/UK/IBM on 19/11/2003 11:36 -----
Discussion
Main Topic
"armagh_elect" <fmcalind@xxxxxxx>
Today 11:16
.
Subject:
.
Re: Fw: [ukha_d] Urgent/Now : Got a Comfort Q !!!
.
Category:
Normally sensors are wired with EOL resistors in series...Have you
got a link to the new alarm panel ???
Frank
--- In ukha_d@xxxxxxx, Gareth Cook <g@u...> wrote:
> Not sure I follow to be honest - i thought everything was in
parallel
> before
>
> G.
>
> Gareth Cook
> SWG EMEA North Account Manager
> IBM SWG - BTE Office - Lotus Park, Staines, TW18 3AG
> Office: +44 (0)1784 445166 - Mobile: +44 (0)7980 445166
> AIM Chat : TheBoyG - MSN Chat : chat@g...
> email: g@xxxxxxx
>
>
> ----- Forwarded by Gareth Cook/UK/IBM on 19/11/2003 11:03 -----
>
> Discussion
> Main Topic
>
> "armagh_elect" <fmcalind@b...>
> Today 09:57
>
> .
> Subject:
> .
> Re: Fw: [ukha_d] Urgent/Now : Got a Comfort Q !!!
> .
> Category:
>
>
>
> If using 6 core you can have the tampers connected seperately and
> then connect all tampers together in the new alarm panel ( all in
> series and a resistor ?)...But you should put the new END OF LINE
> RESISTOR inside the pirs ...in series with the alarm
> contacts....Hope that makes sense...
>
> Frank
>
>
>
>
>
> --- In ukha_d@xxxxxxx, Gareth Cook <g@u...> wrote:
> > ah ok - they PIRs that were in place had 6 core connected and
the
> new PIRs
> > have 6 connections. So then do I NEED the tampers connected ?
> >
> > G.
> >
> > Gareth Cook
> > SWG EMEA North Account Manager
> > IBM SWG - BTE Office - Lotus Park, Staines, TW18 3AG
> > Office: +44 (0)1784 445166 - Mobile: +44 (0)7980 445166
> > AIM Chat : TheBoyG - MSN Chat : chat@g...
> > email: g@xxxxxxx
> >
> >
> > ----- Forwarded by Gareth Cook/UK/IBM on 19/11/2003 09:51 -----
> >
> > Discussion
> > Main Topic
> >
> > "armagh_elect" <fmcalind@b...>
> > Today 09:30
> >
> > .
> > Subject:
> > .
> > Re: Fw: [ukha_d] Urgent/Now : Got a Comfort Q !!!
> > .
> > Category:
> >
> >
> >
> > Hi Gareth
> >
> > EOL....End Of Line resistors ..which are normally
located
> > at the pir sensor...If using Tamper detections usually 2
resistors
> > one across the alarm contact and one in series with the alarm
> > contact and tamper switch (well thats how its done with
> genesis)..sO
> > ONLY NEED 4 CORE CABLE....
> >
> > HTH
> > Frank
> >
> >
> > --- In ukha_d@xxxxxxx, Gareth Cook <g@u...> wrote:
> > > If I knew what that was I could answer :-(
> > >
> > > G.
> > >
> > > Gareth Cook
> > > SWG EMEA North Account Manager
> > > IBM SWG - BTE Office - Lotus Park, Staines, TW18 3AG
> > > Office: +44 (0)1784 445166 - Mobile: +44 (0)7980 445166
> > > AIM Chat : TheBoyG - MSN Chat : chat@g...
> > > email: g@xxxxxxx
> > >
> > >
> > > ----- Forwarded by Gareth Cook/UK/IBM on 19/11/2003 09:26
-----
> > >
> > > Discussion
> > > Main Topic
> > >
> > > "Frank Mc Alinden" <fmcalind@b...>
> > > Today 09:17
> > >
> > > .
> > > Subject:
> > > .
> > > Re: [ukha_d] Urgent/Now : Got a Comfort Q !!!
> > > .
> > > Category:
> > >
> > >
> > >
> > > Does the New Alarm system have the same EOL Resistors as the
> > Comfort ???
> > > they might need to be replaced as well ???
> > >
> > > Just a thought
> > >
> > > Frank
> > > ----- Original Message -----
> > > From: Gareth Cook
> > > To: ukha_d@xxxxxxx
> > > Sent: Wednesday, November 19, 2003 7:58 PM
> > > Subject: Fw: [ukha_d] Urgent/Now : Got a Comfort Q !!!
> > >
> > >
> > > Sort of. We're selling the house with an alarm, so I
bought
a
> > Texe alarm
> > >
> > > to replace the comfort. We've removed the comfort system
and
> > marked what
> > >
> > > all the wires went into, but as yet Im having difficulty
doing
> a
> > walk
> > > test
> > > with just one PIR (Im replacing those too)...
> > >
> > > And also our buyers are playing silly buggers and
demanding
to
> > move in
> > > next monday - 4 days early. Our estate agent requested end
of
> > the month,
> > >
> > > and so did their solicitor. Im pretty sure the guy (being
a
> bit
> > &^%&$&)
> > > will pull out of the whole process.
> > >
> > > So not the clearest of minds to be playing with an alarm
> system !
> > >
> > > G.
> > >
> > > Gareth Cook
> > > SWG EMEA North Account Manager
> > > IBM SWG - BTE Office - Lotus Park, Staines, TW18 3AG
> > > Office: +44 (0)1784 445166 - Mobile: +44 (0)7980 445166
> > > AIM Chat : TheBoyG - MSN Chat : chat@g...
> > > email: g@xxxxxxx
> > >
> > >
> > > ----- Forwarded by Gareth Cook/UK/IBM on 19/11/2003 08:43
---
--
> > >
> > > Discussion
> > > Main Topic
> > >
> > > "Paul Gale" <groups@s...>
> > > Today 08:26
> > >
> > > .
> > > Subject:
> > > .
> > > RE: [ukha_d] Urgent/Now : Got a Comfort Q !!!
> > > .
> > > Category:
> > >
> > >
> > >
> > > Gareth - have you sorted this now?
> > >
> > > Paul.
> > >
> > >
> > > > -----Original Message-----
> > > > From: Gareth Cook [mailto:g@xxxxxxx]
> > > > Sent: 18 November 2003 19:17
> > > > To: ukha_d@xxxxxxx
> > > > Subject: [ukha_d] Urgent/Now : Got a Comfort Q !!!
> > > >
> > > > I'm ripping out Comfort (we're moving house) - but I
have
a
> > question -
> > >
> > > how
> > > > on earth do I map the physical cables to the zones ?
We've
> > labelled
> > > what
> > > > we've removed, but I can't see where it's listed what
these
> > map to
> > > > internally. For example, Z1 on the PCB goes to what
> > internally ? I've
> > > got
> > > > CS-Express but can't see a relation...
> > > >
> > > > If some KIND soul wouldn't mind giving me a call on
my
> mobile
> > below ,
> > > > that'd be much appreciated :-)
> > > >
> > > > Cheers all
> > > >
> > > > G.
> > > >
> > > > (In NEED !)
> > > >
> > > > Gareth Cook
> > > > SWG EMEA North Account Manager
> > > > IBM SWG - BTE Office - Lotus Park, Staines, TW18 3AG
> > > > Office: +44 (0)1784 445166 - Mobile: +44 (0)7980
445166
> > > > AIM Chat : TheBoyG - MSN Chat : chat@g...
> > > > email: g@xxxxxxx
> > > >
> > > >
> > > >
> > > > [Non-text portions of this message have been removed]
> > > >
> > > >
> > > >
> > > > UKHA 2004: 15th and 16th May 2004
> > > >
> > > > http://www.automatedhome.co.uk
> > > > Post message: ukha_d@xxxxxxx
> > > > Subscribe: ukha_d-subscribe@xxxxxxx
> > > > Unsubscribe: ukha_d-unsubscribe@xxxxxxx
> > > > List owner: ukha_d-owner@xxxxxxx
> > > >
> > > > Your use of Yahoo! Groups is subject to
> > > http://docs.yahoo.com/info/terms/
> > > >
> > > >
> > > >
> > >
> > >
> > >
> > > UKHA 2004: 15th and 16th May 2004
> > >
> > > http://www.automatedhome.co.uk
> > > Post message: ukha_d@xxxxxxx
> > > Subscribe: ukha_d-subscribe@xxxxxxx
> > > Unsubscribe: ukha_d-unsubscribe@xxxxxxx
> > > List owner: ukha_d-owner@xxxxxxx
> > >
> > > Your use of Yahoo! Groups is subject to
> > > http://docs.yahoo.com/info/terms/
> > >
> > >
> > >
> > >
> > > [Non-text portions of this message have been removed]
> > >
> > >
> > > Yahoo! Groups Sponsor
> > >
> > >
> > >
> > > UKHA 2004: 15th and 16th May 2004
> > >
> > > http://www.automatedhome.co.uk
> > > Post message: ukha_d@xxxxxxx
> > > Subscribe: ukha_d-subscribe@xxxxxxx
> > > Unsubscribe: ukha_d-unsubscribe@xxxxxxx
> > > List owner: ukha_d-owner@xxxxxxx
> > >
> > > Your use of Yahoo! Groups is subject to the Yahoo! Terms
of
> > Service.
> > >
> > >
> > > [Non-text portions of this message have been removed]
> > >
> > >
> > >
> > > UKHA 2004: 15th and 16th May 2004
> > >
> > > http://www.automatedhome.co.uk
> > > Post message: ukha_d@xxxxxxx
> > > Subscribe: ukha_d-subscribe@xxxxxxx
> > > Unsubscribe: ukha_d-unsubscribe@xxxxxxx
> > > List owner: ukha_d-owner@xxxxxxx
> > >
> > > Your use of Yahoo! Groups is subject to
> > http://docs.yahoo.com/info/terms/
> > >
> > >
> > >
> > >
> > > [Non-text portions of this message have been removed]
> >
> >
> >
> > UKHA 2004: 15th and 16th May 2004
> >
> > http://www.automatedhome.co.uk
> > Post message: ukha_d@xxxxxxx
> > Subscribe: ukha_d-subscribe@xxxxxxx
> > Unsubscribe: ukha_d-unsubscribe@xxxxxxx
> > List owner: ukha_d-owner@xxxxxxx
> >
> > Your use of Yahoo! Groups is subject to
> http://docs.yahoo.com/info/terms/
> >
> >
> >
> >
> > [Non-text portions of this message have been removed]
>
>
>
> UKHA 2004: 15th and 16th May 2004
>
> http://www.automatedhome.co.uk
> Post message: ukha_d@xxxxxxx
> Subscribe: ukha_d-subscribe@xxxxxxx
> Unsubscribe: ukha_d-unsubscribe@xxxxxxx
> List owner: ukha_d-owner@xxxxxxx
>
> Your use of Yahoo! Groups is subject to
http://docs.yahoo.com/info/terms/
>
>
>
>
> [Non-text portions of this message have been removed]
UKHA 2004: 15th and 16th May 2004
http://www.automatedhome.co.uk
Post message: ukha_d@xxxxxxx
Subscribe: ukha_d-subscribe@xxxxxxx
Unsubscribe: ukha_d-unsubscribe@xxxxxxx
List owner: ukha_d-owner@xxxxxxx
Your use of Yahoo! Groups is subject to http://docs.yahoo.com/info/terms/
[Non-text portions of this message have been removed]
Home |
Main Index |
Thread Index
|