RE: BT Socket Master->Slave Conversion



> -----Original Message-----
> From: Robert Welsh [mailto:bob-ukha@xxxxxxx]
>
> (This might be one for Mr Doxey....)
>
> Due to being a complete spanner, I went and bought a master phone
socket
> when I should have bought a slave one (cue continuous ringing of the
> phone !).
>
> So rather than paying a fiver to get a £3 part shipped to me, is there
a
> quick way to convert one to the other.
>

Conversion is easy.

Snip out the capacitor.
Snip out the resistor if there is one there.

If there is a lightning arrestor in there you can leave that. the more
lightning protection you have the better.

BUT...

... that wont solve your problem. If you have continuous ringing you have
got 2&5 crossed somewhere or there is an earth on 3.

http://www.diyha.co.uk/telephones/pots.html

Hope that helps

Keith

www.kat5.tv
www.diyha.co.uk



UK Home Automation Meet 2004 - BOOK NOW!
http://www.ukha2004.com

http://www.automatedhome.co.uk
Post message: ukha_d@xxxxxxx
Subscribe:  ukha_d-subscribe@xxxxxxx
Unsubscribe:  ukha_d-unsubscribe@xxxxxxx
List owner:  ukha_d-owner@xxxxxxx

Home | Main Index | Thread Index

Comments to the Webmaster are always welcomed, please use this contact form . Note that as this site is a mailing list archive, the Webmaster has no control over the contents of the messages. Comments about message content should be directed to the relevant mailing list.