RE: Re: New UK Building Regs. Will Outlaw DIY Wiring
A lot of what you mention was standard practice.
No lighting circuits had earths. Twin flex was commonly used, which does
look like speaker cable.
Joints were often done with ceramic screw things. Regs now state no joints
in a new install.
Dean.
Try our amazing lighting demonstration online now, and watch in
realtime via our webcam. Click below and follow the CBus links.
www.rolec.net
dean@xxxxxxx
Tel: 01908-210677
Fax: 01908-210678
The information in this internet E-mail is confidential and is intended
solely for the addressee. Access, copying or re-use of information in it by
anyone else is unauthorised. Any views or opinions presented are solely
those of the author and do not necessarily represent those of The Rolec
Group or any of its affiliates. If you are not the intended recipient
please
contact wrongmail@xxxxxxx
-----Original Message-----
From: Graham Howe [mailto:graham@xxxxxxx]
Sent: 18 March 2004 12:19
To: ukha_d@xxxxxxx
Subject: [ukha_d] Re: New UK Building Regs. Will Outlaw DIY Wiring
> How many local electricians will have seen any HA installs ? I can
hear the
> sharp intake of breath from the local guy and bill going through
the roof as
> I type :-)
Exactly the reason I did my install myself, I can't imagine what
your average sparks would have thought of running every single light
and light switch back to one of three big distribution boards.
However I am 100% sure that what I have installed is much safer than
the rubbish that was there before. After all I don't think that a
ceiling light supplied by speaker wire coming from a 'junction box'*
with 5 mains spurs comming out of it, was quite up to regs anyway!
I am still amazed at how the house has managed to survive this long
with wiring that broke every rule in the book, not a single earth to
any light or switch and plenty of wood chips, horse hair and straw
under every floor board.
* junction box is not actually the best way of describing several
connector blocks of differing sizes all linked together and wrapped
up lots of oozing old insulation tape. However the tape did do a
reasonable job of holding the wires in place where screws had been
overlooked. And I do miss the high tech pressure activated lighting
in the dining room which would blink on and off as the kids ran
around upstairs ;-)