[Message Prev][Message
Next][Thread Prev][Thread Next][Message
Index][Thread Index]
RE: House power and damaging kit!!!
- Subject: RE: House power and damaging kit!!!
- From: "Keith Doxey" <ukha@xxxxxxxxxxx>
- Date: Tue, 22 Aug 2006 14:52:23 +0100
Hi Paul,
Do the failed items all have Switched Mode Power Supplies ?
If so, it is probably just due to heat. Capacitors in the startup circuit
of
an SMPS can dry out due to the heat and will continue to run as long as
power is not removed. Once the power fails, the PSU will not start up
again.
PACE Analogue Satellite Receivers suffered quite badly from this as they
often ran at elevated temperatures due to poor air circulation in AV
cabinets. After a power failure they would die but unfortunately not
silently. They used to go with a very large BANG that took out several
components including the transformer.
HTH
Keith
> -----Original Message-----
> From: Paul Gale [mailto:groups@xxxxxxx]
> Sent: 22 August 2006 14:45
> To: ukha_d@xxxxxxx
> Subject: [ukha_d] House power and damaging kit!!!
>
>
> A couple of times now, turning off the main house power and
> restoring it has somehow damaged kit, I guess from a surge.
>
> First time was last year when my heating controller (linked to
> Comfort) was damaged and yesterday, one of my network switches.
>
> Should this be allowed to happen in a standard house wiring
> scenario ? I guess there?s nothing to stop it???
>
> So ? is there anything I can fit the the house electrics that
> will stop this happening again?
>
> Thanks,
>
> Paul.
>
>
>
>
>
> [Non-text portions of this message have been removed]
>
>
>
>
> Yahoo! Groups Links
>
>
>
>
>
>
>
UKHA_D Main Index |
UKHA_D Thread Index |
UKHA_D Home |
Archives Home
|