Re: Integrating BT Home Monitor VP1000/Visonic to Homeseer
Hmm, that's what I thought. I will have to wait and see how reliable
this
is. It just depends if a keyfob arm/disarm command is missed at any time.
So far I'm impressed. Especially as I can just buy the sensors and use them
as a cheap way of getting info into homeseer (no alarm use). Curtains, cat
flap, doors etc...
On 8/23/06, Craig <craigc.lists@xxxxxxx> wrote:
>
> > One for Craig - does the Powermax alarm console transmit any
> > codes, or is it only the sensors?
>
> Just the sensors (door, PIR, etc)& keyfobs transmit RF. Sensors
appear to
> send a 'normal' heatbeat every so often, that includes battery level
info.
>
> I did have the alarm panel/console configured to transmit X10 via
XM10U so
> I
> could get alarm state from the panel into homeseer, but did not like
the
> solution due to the number of devices involved, and latency of X10:
>
> PIR/keyfob -> Panel -> XM10U -> X10 -> CM12 -> Homeseer
>
> The rfxcom solution is now a lot simpler, I get the state of the panel
> mirrored in homeseer, from the keyfobs
>
> PIR/keyfob -> Panel
> PIR/keyfob -> RFXCOM -> Homeseer
>
>
>
> HTH
>
>
>
>
>