[Message Prev][Message
Next][Thread Prev][Thread Next][Message
Index][Thread Index]
Re: [OT] Help! new switch and routing
Paul,
With 192.168.0.1 as your gateway, this suggests that you have a netmask
of 255.255.255.0, in effect this means that the switch is on a different
network, at least as far as TCP/IP is concerned.
The quickest solution would be to manually give a PC an IP of
192.168.2.9 netmask of 255.255.255.0, then use the admin interface of
the switch to give it an ip in the range 192.168.1.x.
Everything is behaving exactly as it should.
Stuart
On Tue, 2006-08-22 at 12:21 +0100, Paul Gale wrote:
> I plugged my new 24 port gig switch in this morning (SMCGS24C-Smart)
its a managed (or rather smart) switch.
>
> All PCs working OK but Im trying to get to the web management console
in it but having huge problems. The IP is 192.168.2.10/255.255.255.0 by
default but I cant get to it. If I ping that IP, ping shows a reply from
either my default gateway when my ADSL lines are down (192.168.0.1) or an
IP at my ISP (84.45.193.194) when the lines are up !!!!
>
> I restarted all the PCs, Linux router, W2K3 Server etc but no
difference.
>
> Is this a weird routing problem? Any ideas?
>
> Thanks,
>
> Paul.
>
>
>
>
>
> [Non-text portions of this message have been removed]
>
>
>
>
>
>
>
> Yahoo! Groups Links
>
>
>
>
>
>
--
Stuart Poulton <stuart.poulton@xxxxxxx>
UKHA_D Main Index |
UKHA_D Thread Index |
UKHA_D Home |
Archives Home
|