[Message Prev][Message
Next][Thread Prev][Thread Next][Message
Index][Thread Index]
RE: Heating HA Possibilities ?
> I'm curious at to what options we may be able to consider to
> tie this into CBUS/Comfort for automation - would it be just
> a case of parallel wiring into a relay module ? Or would it
> be better to parallel wire into the actual button on the
> front (the manual override button) ala the garage door opener
> (http://palmlodge.com/lookup/Comfort+to+Garage+Door)
I don't have comfort or cbus, but I would consider a different approach to
HA control of the heating, via the roomstat.
I replaced my mechanical stat with a remote controllable heatmiser (about
40
quid IIRC).
The heating is set to 'cont' ie on all the time, and the heatmiser
schedules
the temp for different times of day night.
I have remote control of temp via harmony remote to override temp setting,
I
can send a discrete IR command to set temp from 18-30deg from customised
buttons on the remote.
I plan to use some sort of IR control from HA server (USBIRT?) to add more
intelligent control, but I assume you could use comfort IR?
I saw the advantage of using IR as it meant I did not need to interfere
with
the heating controls, and gives opto-isolation to the controller.
UKHA_D Main Index |
UKHA_D Thread Index |
UKHA_D Home |
Archives Home
|