RE: Dimmer switches



Lol - true HA reply ;)

Paul.

> -----Original Message-----
> From: ukha_d@xxxxxxx [mailto:ukha_d@xxxxxxx] On Behalf
> Of Nigel Giddings
> Sent: 21 August 2008 11:06
> To: ukha_d@xxxxxxx
> Subject: RE: [ukha_d] Dimmer switches
>
> Tim,
>
>
>
> Why do something simply when it could be more complicated?
>
>
>
> Have you considered using a remote dimmer with a 1K Potentiometer in
> you
> wall plate that could adjust the 0-10v control line on the remote
> dimmer.
>
>
>
> You would need to run two low voltage/low current wires from the Pot
to
> the dimmer and you could have as big a dimmer as you like. I had my
> dimmers doing this temporarily until I installed the C-Bus 0-10v
> interfaces...
>
>
>
> http://en.wikipedia.org/wiki/0-10_V_lighting_control
>
>
>
> HTH
>
> Nigel
>
>
>
> -----Original Message-----
> From: ukha_d@xxxxxxx [mailto:ukha_d@xxxxxxx] On Behalf
> Of Tim Hawes
> Sent: 21 August 2008 08:44
> To: ukha_d@xxxxxxx
> Subject: [ukha_d] Dimmer switches
>
>
>
> What's the highest rated 2gang rotary dimmer that fits into a UK
single
> box?
> Most that I've found seem to be either 400W for 1 dimmer, or 250W each
> for a pair on the same plate. I have two ceiling lights, each with 5
> bulbs but the brightness is limited since I can't exceed the rating of
> the dimmer. I could split them onto separate switches but it's
> convenient to control them together and I like the rotary action,
> which I think rules out X10?
>
> The second output from the switch is for the wall lights, and the
> bulbs are regular filament ones - no low energy malarkey...
>
> Thanks,
>
> Tim.
>
>
>
>
>
> [Non-text portions of this message have been removed]
>
>
> ------------------------------------
>
> **** Sponsored By http://www.Berble.com ****
> ****       Computers You Carry          ****
>
>
>
>
>
>
>
> __________ Information from ESET NOD32 Antivirus, version of virus
> signature database 3373 (20080821) __________
>
> The message was checked by ESET NOD32 Antivirus.
>
> http://www.eset.com
>


__________ Information from ESET NOD32 Antivirus, version of virus
signature database 3374 (20080821) __________

The message was checked by ESET NOD32 Antivirus.

http://www.eset.com


------------------------------------


UKHA_D Main Index | UKHA_D Thread Index | UKHA_D Home | Archives Home

Comments to the Webmaster are always welcomed, please use this contact form . Note that as this site is a mailing list archive, the Webmaster has no control over the contents of the messages. Comments about message content should be directed to the relevant mailing list.