  • Subject: Re: Netiom-xAP
  • From: "Rob Kearns" <robkearns@xxxxxxxxx>
  • Date: Thu, 09 Jun 2005 20:01:19 -0000

Hi Kevin,

Thanks for the reply.

I downloaded James's Floorplan and used it to control the netiom,
which it did perfectly.

So after that I downloaded the xap GuiHub which reported that my
messages were malformed. They had a trailing hex zero on the end.

After fixing the message it now shows up in the hub window as ok but
does not get a response from the netiom. If I hit the resend button in
the hub then it works fine and gets an info message in response from
the netiom!

Does anyone have any ideas as I'm pulling my hair!

Thanks
Rob
--- In xap_automation@xxxxxxx, "KevinT" <kevin@n...> wrote:
> Using Jamse's Floorplan to chjange an output
>
> xap-header
> {
>     v=12
>     hop=1
>     uid=FF111200
>     class=xAPBSC.cmd
>     source=mi4.floor.NEBULA
>     target=phaedrus.netiom.location:output.16
> }
> Output.State.1
> {
>     id=*
>     state=On
> }
>
>
> HTH
> Kevin
>
>   -----Original Message-----
>   From: xap_automation@xxxxxxx
> [mailto:xap_automation@xxxxxxx]On
Behalf Of Rob Kearns
>   Sent: 05 June 2005 19:18
>   To: xap_automation@xxxxxxx
>   Subject: [xap_automation] Netiom-xAP
>
>
>   Hi,
>
>   I'm having trouble controlling the outputs on my Netiom. There are
>   three ways of identifying the target device, uid, target and key
>   values in the message, and I'm a bit confused as to when to use
them.
>
>   I've tried the following messages without luck:
>
>   xap-header
>   {
>   hop=1
>   target=phaedrus.netiom.Location
>   v=12
>   source=rk.test.source
>   class=xAPBSC.cmd
>   uid=FF123400
>   }
>   outputs.state
>   {
>   Output.1=On
>   }
>
>   xap-header
>   {
>   hop=1
>   target=phaedrus.netiom.Location:output.1
>   v=12
>   source=rk.test.source
>   class=xAPBSC.cmd
>   uid=FF123411
>   }
>   output.state
>   {
>   state=On
>   }
>
>   xap-header
>   {
>   hop=1
>   target=phaedrus.netiom.Location
>   v=12
>   source=rk.test.source
>   class=xAPBSC.cmd
>   uid=FF123400
>   }
>   global.state
>   {
>   outputs=On
>   }
>
>   I'm using my own program to send the messages so it could be
something
>   obvious that I've overlooked or a malformed message. All lines are
>   terminated with a lf.
>
>   Any help would be appreciated.
>
>   Thanks
>
>
>
>
>
>
>
----------------------------------------------------------------------------
> --
>   Yahoo! Groups Links
>
>     a.. To visit your group on the web, go to:
>     http://groups.yahoo.com/group/xap_automation/
>
>     b.. To unsubscribe from this group, send an email to:
>     xap_automation-unsubscribe@xxxxxxx
>
>     c.. Your use of Yahoo! Groups is subject to the Yahoo! Terms of
Service.







xAP_Automation Main Index | xAP_Automation Thread Index | xAP_Automation Home | Archives Home

Comments to the Webmaster are always welcomed, please use this contact form . Note that as this site is a mailing list archive, the Webmaster has no control over the contents of the messages. Comments about message content should be directed to the relevant mailing list.