Marty,
This update should fix the issue. If it's unable to locate the pc name
then 'server' is used instead, but you'll be able to change the name in
the Settings.txt file in the xAP folder within HomeSeer if you need to.
http://www.mi4.biz/files/xaphomeseer/xaphomeseertest3.zip
Can you let me know if it works ok?
Also, to anyone who uses HomeSeer along with either xAP TV or
Switchboard, I've included in this new HomeSeer ocx the relevant
messages to link the web interfaces together using the xAP Intranet system.
James
shankmarty wrote:
>James,
>Thanks for the quick response.
>I am running Win98 as it is a old PC that I put under the
>stairs that just runs homeseer.
>Its name is "Closet" and can network the drives fine on my
other
>computers. The system properties does not show the computer name
>like XP. You need to go to -> control panel -> Click the Network
>icon -> then hit the Identification Tab.
>
>Marty
>--- In xap_automation@xxxxxxx, James <james@m...> wrote:
>
>
>>Hi,
>>
>>source=mi4.homeseer..116
>>
>>Between the .. should be the name of the pc that is running
>>
>>
>HomeSeer. If you go to the windows system properties (windows
>key+Break) is anything set? If it is could you let me know the
>version of Windows and i'll see why it not being picked up. I will
>also get a way of overriding the name setable somewhere.
>
>
>>James
>>
>>
>>
>>
>>shankmarty wrote:
>>
>>
>>
>>>All,
>>>I posted this on the homeseer forum and thought I would try
here
>>>
>>>
>as
>
>
>>>well...
>>>----------------------------------------------------------
>>>I am trying to get homeseer to talk to Xlobby (different PC)
with
>>>the new plugin.
>>>I have narrowed the problem down that the Xap conduit on
homeseer
>>>does not have its address configed properly. See below for one
of
>>>the xAP conduit status messages going out:
>>>
>>>xap-header
>>>{
>>>v=12
>>>hop=1
>>>uid=FF416304
>>>class=xAPBSC.event
>>>source=mi4.homeseer..116:Outside.Temperature
>>>}
>>>output.state
>>>{
>>>State=ON
>>>Text=53.8
>>>}
>>>
>>>Its missing the field after "mi4.homeseer.".
>>>What did I forget to configure so it shows the PC location?
>>>
>>>Thanks.
>>>
>>>
>>>
>>>
>>>
>>>
>>>