The UK Home Automation Archive

Archive Home
Group Home
Search Archive


Advanced Search

The UKHA-ARCHIVE IS CEASING OPERATIONS 31 DEC 2024


[Message Prev][Message Next][Thread Prev][Thread Next][Message Index][Thread Index]

Re: Homeseer 2 Plugin Question



As a side note to this. I was no longer receiving updates so I did the
following..

Stopped Homeseer Service
Stopped xAP Hub Service
Stopped Quasar Application

Started xAP Hub Services
Started Quasar Application
Started Homeseer Services

I then noticed I had "New Hardware" in xAP config (even though
the
original device was still in Homeseer).

Added the new device and got the following in the logs (with debug on)

02/09/2005 19:25:37   xAP Conduit  Set status 30.69
02/09/2005 19:25:37   xAP Conduit  HSEVENT
Ismenuclick=false64,[4,30.69,,,,
02/09/2005 19:25:37   xAP Conduit  HSEVENT =64
02/09/2005 19:25:37   xAP Conduit  HSEVENT =64,[4,30.69,,,,
02/09/2005 19:25:37   xAP Conduit  Device is homeserver com3 one
temperature.current temp
02/09/2005 19:25:37   xAP Conduit  xAP Engine Go Input (5,30.69)
02/09/2005 19:25:37   xAP Conduit
ersp.telemetry.homeserver.com3:one-xap-temp.notification-temperature.current-unit-C

02/09/2005 19:25:37   Database Item  There were errors generated
during the save of the database item. Please consult this log for more
details and report any data loss to HomeSeer Technologies.
02/09/2005 19:25:37   xAP Conduit  Incoming message Stage 4 - First
message check
02/09/2005 19:25:37   xAP Conduit
ersp.telemetry.homeserver.com3:one-xap-temp.notification-temperature.current-location-One

02/09/2005 19:25:37   xAP Conduit  Incoming message Stage 4 - First
message check
02/09/2005 19:25:37   xAP Conduit
ersp.telemetry.homeserver.com3:one-xap-temp.notification-temperature.current-seq-2

02/09/2005 19:25:37   xAP Conduit  Incoming message Stage 4 - First
message check
02/09/2005 19:25:37   xAP Conduit
ersp.telemetry.homeserver.com3:one-xap-temp.notification-temperature.current-temp-30.69

02/09/2005 19:25:37   xAP Conduit  Incoming message Stage 4 - First
message check
02/09/2005 19:25:37   xAP Conduit
ersp.telemetry.homeserver.com3:one-xap-temp.notification-temperature.current--

02/09/2005 19:25:37   xAP Conduit  Incoming message Stage 4 - First
message check
02/09/2005 19:25:37   xAP Conduit  Incoming message Stage 3 - Post
known hardware check
02/09/2005 19:25:37   xAP Conduit  xAP message
ERSP.telemetry.homeserver.com3:One(xap-temp.notification)
02/09/2005 19:25:37   xAP Conduit  Incoming message Stage 2 - Post
header extraction and Iam ignore
02/09/2005 19:25:37   xAP Conduit  Re processing last xAP message
02/09/2005 19:25:37   xAP Conduit  mid1 new device0
02/09/2005 19:25:37   Database Item  Device Comparison Error 5, field
name : Cannot set column 'name' to 'homeserver one homeserver com3 one
temperature.current temp'. The value violates the MaxLength limit of
this column. Exception:Cannot set column 'name' to 'homeserver one
homeserver com3 one temperature.current temp'. The value violates the
MaxLength limit of this column.
02/09/2005 19:25:37   Database Item  Saving Device homeserver one
homeserver com3 one temperature.current temp
02/09/2005 19:25:37   xAP Conduit  Created new device homeserver
homeserver com3 one temperature.current temp
02/09/2005 19:25:37   xAP Conduit  Using [4
02/09/2005 19:25:37   xAP Conduit  Trying [4-4
02/09/2005 19:25:37   xAP Conduit  Skipped (HS says it exists)[3-17-
02/09/2005 19:25:37   xAP Conduit  Trying [3-3
02/09/2005 19:25:37   xAP Conduit  Skipped (HS says it exists)[2-15-
02/09/2005 19:25:37   xAP Conduit  Trying [2-2
02/09/2005 19:25:37   xAP Conduit  Skipped (HS says it exists)[1-12-
02/09/2005 19:25:37   xAP Conduit  Trying [1-1
02/09/2005 19:25:37   xAP Conduit  Creating new device homeserver com3
one temperature.current temp([)


The error is still there, but hopefully more helpful information.

Cheers

Marc



--- In xap_automation@xxxxxxx, "marcrfuller"
<yahoogroups@s...> wrote:
> --- In xap_automation@xxxxxxx, Kevin Hawkins <lists@u...> wrote:
> >
> >  Kevin Hawkins wrote:
> >
> > >Marc - the version of the xAP plugin you are using is 2.0.182
??
> > >(About Tab)
> > >
> > >
> > Hmm - just revisited your first post - you are :-)
> >
> > Might have to see what James says on this ...
> >
> > (I note the network UID is FE but that's just out of interest and
not
> > related to this problem)
> >
> >
>
> Yeah I'm running the latest version 2.0.0.182 :)
>
>
> > K
> >
> > >The xAp message u sent doesn't generate HS errors for me....
> > >
> > >02/09/2005 16:45:57 ~!~xAP Conduit~!~Created new device
homeserver
> > >homeserver com3 one temperature.current temp
> > >02/09/2005 16:45:57 ~!~Database Item~!~Saving Device
homeserver one
> > >homeserver com3 one temperature.current temp
> > >02/09/2005 16:45:58 ~!~xAP Conduit~!~Created new device
homeserver
> > >homeserver com3 one temperature.current unit
> > >02/09/2005 16:45:58 ~!~Database Item~!~Saving Device
homeserver
> com3 one
> > >temperature.current unit
>
> That's strange.. I wonder why it does with mine... every single time I
> get the error so it's easily duplicated.
>
> Cheers
>
> Marc





xAP_Automation Main Index | xAP_Automation Thread Index | xAP_Automation Home | Archives Home

Comments to the Webmaster are always welcomed, please use this contact form . Note that as this site is a mailing list archive, the Webmaster has no control over the contents of the messages. Comments about message content should be directed to the relevant mailing list.