Re: more questions!


  • Subject: Re: more questions!
  • From: "rleong1" <rleong1@xxxxxxxxx>
  • Date: Mon, 28 Aug 2006 16:48:57 -0000

here's a couple messages that goes thru.  same format as the failing
one, but these are among the first 8 devices i send xpl messages for.
i notice the uids have changed.  the failing ones all have FF486200.
i guess something isn't correctly updating the uid beyond 8 devices?

xap-header
{
v=12
hop=1
uid=FF486201
class=xapbsc.info
source=xpl.pts.starcom.home:officelampr
}
output.state
{
state=On
level=0
}


xap-header
{
v=12
hop=1
uid=FF486205
class=xapbsc.info
source=xpl.pts.starcom.home:sinklight
}
output.state
{
state=On
level=0
}

--- In xap_automation@xxxxxxx, James <james@...> wrote:
>
> Could you send me some example sensor.basic messages that you are
> sending? Including some that get through and some that don't.
> There should be no reason why they don't get transfered as long as
it's
> less than 254 devices (uid limit). When you say UID error, i presume
> this is from Viewer?  does it actually say what the error was,  I'm
> guessing it is an incorrect number of characters, probably something
to
> do with decimal to hex conversion...somewhere
>
> James
>








xAP_Automation Main Index | xAP_Automation Thread Index | xAP_Automation Home | Archives Home

Comments to the Webmaster are always welcomed, please use this contact form . Note that as this site is a mailing list archive, the Webmaster has no control over the contents of the messages. Comments about message content should be directed to the relevant mailing list.