Bit of a co-incidence - I was just about to write a post about the
same
subject as Andy.
I am convinced there is an issue regarding links in my setup having played
around quite a bit. I also continue to have page loading issues even though
I have upgraded to the latest intranet.ocx - it is better but not
completely
solved.
I have setup up a link between a PIR and a light. Set it to "Any
change
always turn on", run for "20 minutes" and
"linked". It seems to work fine
for a while but eventually it continues to respond to the PIR event but
only
stays on for a second or so.
I looked in the viewer and the floorplan is definitely sending an off event
almost immediately which shouldn't be possible if my understanding of the
logic is correct since I don't have a toggle situation and hence external
events can't cause the behaviour I am seeing.
Running WIN2k, latest floorplan.
Would collecting a trace be useful?
Cheers
Shane
-----Original Message-----
From: xap_automation@xxxxxxx
[mailto:xap_automation@xxxxxxx]On
Behalf Of Kevin Hawkins
Sent: Thursday, 18 May 2006 10:34 a.m.
To: xap_automation@xxxxxxx
Subject: Re: [xap_automation] xAP Floorplan
Andy Laurence wrote:
> James <mailto:james@xxxxxxx> wrote:
>
>
>> The toggle problem is usually on that duplicate xAP toggle
>> messages are being sent. This can occur when the xAP hub gets
>> bound to multiple network cards. You mentioned GSX is loaded
>> and the virtual nics that it loads would cause the issuse.
>> It's easily fixed though by a couple of additional lines in
>> the hub's config file. A how to is available here:
>>
>> http://groups.yahoo.com/group/xap_automation/message/563
>>
>
> The virtual machine that has Floorplan (and the hub) installed has
only
> one interface (virtual, of course). The host has a number of
> interfaces, but these are just for binding the vitual machines to the
> physical adapter. I'll have a play around, and see what I can come up
> with. Thanks for the speedy reply, and really quite helpful
> suggestions!
>
>
You'll be able to see if this is a problem by running xAP Viewer
somewhere (preferably on a different PC to Floorplan ) and watching what
happens when you click 'toggle' - the series of xAP messages that occur
should give a good idea what is happening - if you do see two xAPBSC.cmd
messages with state=toggle in them then you have something duplicating
them somewhere..
Kevin