Re: Trigger an output on TTS?
OK - I'm not actually running SB or HS at the moment to test this but
if
you had created something in HS based on probably the 'say' parameter
will be recognising it based on it being within a tts.stop block - ie a
tts.start wouldn't update the variable, and hence the device. Also it is
possible that none of those variables have actually changed from the
last time a tts.stop was received so you need to trigger your script
based on 'update' rather than 'change' - (you will see that the last
updated time changes each time)
K
Paul Gale wrote:
> Oh, and the other bit I don't understand - how to listen for the TTS
Stop message? Do I create a device or have to do something in scripting
etc?
>
> At first I thought I could create a device but on selecting the
mi4.speech.haserver device, I got the following in the raw mode:
>
> xap-header
> {
> v=12
> UID=FF234500
> Class=tts.speak
> Source=mi4.speech.HASERVER
> }
> tts.stop
> {
> volume=100
> card=kX Wave SB0240 10k2 [d080] 4/5
> say=Enter text to speak
> voice=NeoSpeech Paul
> }
>
> I could only select devices for the variables: volume, card etc - I
guess I'm on the wrong track here? How do I just intercept the tts.stop
message each time and then do something?
>
> Many thanks,
>
> Paul.
>
>
>
>
>> -----Original Message-----
>> From: xap_automation@xxxxxxx
>> [mailto:xap_automation@xxxxxxx] On
Behalf Of Kevin Hawkins
>> Sent: 22 October 2006 13:43
>> To: xap_automation@xxxxxxx
>> Subject: Re: [xap_automation] Trigger an output on TTS?
>>
>> Well it's afternoon just - and I've managed the papers too !
>>
>> First off HS will be able to achieve almost anything you need in
>> connection with xAP. It can intercept any xAP message (event) ,
make
>> some decisions (script) and do something else eg send xAP
(action). This
>> is the fundamental way all HA tasks work really but the 'script'
bit in
>> the middle is where most people get a little stumped. In
anything but
>> the simplest HA setup, particularly with xAP getting familiar
with a
>> scripting language is a necessary chore, but very rewarding. It
also
>> helps where you need permutations of interactions that the
software
>> doesn't support out of the box. So you could create a HS device
from
>> the xAP TTS start message and trigger a script when it changes
state to
>> link it to your HomeVision output but I'm thinking there's a
neater way
>> in this instance....
>>
>> First of all you should xAP enable the HomeVision
(relay>Russound)
>> output via HomeSeer. This will expose the HV output as a xAP BSC
Binary
>> output. Now you can send xAPBSC.cmd messages on your network ,
targeted
>> at this and it will change state accordingly. The target address
will
>> actually be a HomeSeer address of course. Now within xAP
SwitchBoard
>> there a very flexible feature (thanks J !) where you can add any
xAP
>> messages you want sent into a text file and they will be sent in
>> response to the appropriate event. You will find a file called
>> tosend.txt that in your case you probably have already edited to
include
>> a xAP TTS message. What we will do here is add a xAPBSC.cmd
message as
>> the very first thing that gets sent to the HV output to switch
your
>> relay. This will need adding as a 'raw' xAP message. Now each
time,
>> just before the TTS is sent your relay will get turned on, you
will also
>> later have to turn it off when the TTS stop is sent. There may
still be
>> a delay issue but the relay should change fairly instantaneously
and the
>> TTS message has to be received, processed, built and spoken so I'm
>> hopeful this will actually add enough inherent delay to actually
make it
>> all work just as you want it.
>>
>> If you find it confusing as to how to add the raw BSC cmd to
>> SwitchBoards' tosend.txt file then if you go ahead and create
your BSC
>> HV output in HS and let me know what it's address is I will show
you
>> what you need to add to the file. Please test the BSC output with
some
>> BSC cmd messages sent using Viewer to make sure it's working as
expected
>> of course. Easiest probably to use a state=toggle command rather
than
>> having to use two messages (state=on state=off) - you should see
>> corresponding xAPBSC.event messages for each command and your
relay
>> should click as it changes state of course.
>>
>> Here is the format of a generic xAPBSC./cmd message - you just
need to
>> edit the target line to match your address... I have wildcarded
the ID=
>> parameter to make it easier .
>>
>> xap-header
>> {
>> v=12
>> hop=1
>> uid=FF123400
>> class=xAPBSC.cmd
>> source=ACME.Controller.Central
>> target=mi4.HomeSeer.PaulG.whatever:RussoundRelay
>> }
>> output.state.1
>> {
>> ID=*
>> State=TOGGLE
>> }
>>
>>
>>
>> Just another caveat - if you are attaching a relay to a HV output
ensure
>> it has a protection diode across it so that it doesn't blow your
output.
>> The HV docs have details on this. IIRC you have a HV Pro though
and
>> these already have onboard relays with LED's so that it makes it
much
>> easier :-)
>>
>> K
>>
>> Paul Gale wrote:
>>
>>> I shall wait until the effects have worn off then - hope the
headache
>>>
>> isn't too bad! ;)
>>
>>> Paul.
>>>
>>>
>>>
>>>
>>>
>>>> -----Original Message-----
>>>> From: xap_automation@xxxxxxx
>>>> [mailto:xap_automation@xxxxxxx] On
Behalf Of Kevin Hawkins
>>>> Sent: 22 October 2006 03:53
>>>> To: xap_automation@xxxxxxx
>>>> Subject: Re: [xap_automation] Trigger an output on TTS?
>>>>
>>>> A rather 'well gone' reader was about to reply to this at
4AM on my
>>>> crawling back home but has fortunately remembered from
past experience
>>>> it's better to wait till tomorrow (afternoon probably)
! ;-)
>>>>
>>>> K
>>>>
>>>> Paul Gale wrote:
>>>>
>>>>
>>>>> James,
>>>>>
>>>>> I've been playing with Speech and the xAP HS plugin -
not sure how you
>>>>>
>>>>>
>>>> can trap the tts.start and tts.stop messages and then do
something when
>>>> they're received - is this actually possible?
>>>>
>>>>
>>>>> Thanks,
>>>>>
>>>>> Paul.
>>>>>
>>>>>
>>>>>
>>>>>
>>>>>
>>>>
>>>> Yahoo! Groups Links
>>>>
>>>>
>>>>
>>>>
>>>>
>>>
>>>
>>> Yahoo! Groups Links
>>>
>>>
>>>
>>>
>>>
>>>
>>>
>>>
>>
>>
>>
>> Yahoo! Groups Links
>>
>>
>>
>>
>
>
>
>
> Yahoo! Groups Links
>
>
>
>
>
>
>
xAP_Automation Main Index |
xAP_Automation Thread Index |
xAP_Automation Home |
Archives Home
|