RE: xAP hub 2 errors



I just tried the GUI hub (stopped all xAP app and the hub service),
but it didn't seem to want to start - message bottom left was
"starting" but wasn't receiving messages. It's own heart beats
were there but nothing else.

No firewall or A/V enabled on this PC.

Any ideas?

Paul.



> -----Original Message-----
> From: xap_automation@xxxxxxx
> [mailto:xap_automation@xxxxxxx] On
Behalf Of Paul Gale
> Sent: 11 June 2007 08:52
> To: xap_automation@xxxxxxx
> Subject: RE: [xap_automation] xAP hub 2 errors
>
> Not sure if it relates to the hub but I just had another error message
> from the hub:
>
> Event Type:	Error
> Event Source:	.NET Runtime 2.0 Error Reporting
> Event Category:	None
> Event ID:	5000
> Date:		09/06/2007
> Time:		13:37:11
> User:		N/A
> Computer:	HASERVER
> Description:
> EventType clr20r3, P1 hub.exe, P2 2.0.2707.27141, P3 465ee40a, P4
> system, P5 2.0.0.0, P6 4333ae87, P7 374c, P8 131, P9
> system.componentmodel.win32, P10 NIL.
>
> For more information, see Help and Support Center at
> http://go.microsoft.com/fwlink/events.asp.
> Data:
> 0000: 63 00 6c 00 72 00 32 00   c.l.r.2.
> 0008: 30 00 72 00 33 00 2c 00   0.r.3.,.
> 0010: 20 00 68 00 75 00 62 00    .h.u.b.
> 0018: 2e 00 65 00 78 00 65 00   ..e.x.e.
> 0020: 2c 00 20 00 32 00 2e 00   ,. .2...
> 0028: 30 00 2e 00 32 00 37 00   0...2.7.
> 0030: 30 00 37 00 2e 00 32 00   0.7...2.
> 0038: 37 00 31 00 34 00 31 00   7.1.4.1.
> 0040: 2c 00 20 00 34 00 36 00   ,. .4.6.
> 0048: 35 00 65 00 65 00 34 00   5.e.e.4.
> 0050: 30 00 61 00 2c 00 20 00   0.a.,. .
> 0058: 73 00 79 00 73 00 74 00   s.y.s.t.
> 0060: 65 00 6d 00 2c 00 20 00   e.m.,. .
> 0068: 32 00 2e 00 30 00 2e 00   2...0...
> 0070: 30 00 2e 00 30 00 2c 00   0...0.,.
> 0078: 20 00 34 00 33 00 33 00    .4.3.3.
> 0080: 33 00 61 00 65 00 38 00   3.a.e.8.
> 0088: 37 00 2c 00 20 00 33 00   7.,. .3.
> 0090: 37 00 34 00 63 00 2c 00   7.4.c.,.
> 0098: 20 00 31 00 33 00 31 00    .1.3.1.
> 00a0: 2c 00 20 00 73 00 79 00   ,. .s.y.
> 00a8: 73 00 74 00 65 00 6d 00   s.t.e.m.
> 00b0: 2e 00 63 00 6f 00 6d 00   ..c.o.m.
> 00b8: 70 00 6f 00 6e 00 65 00   p.o.n.e.
> 00c0: 6e 00 74 00 6d 00 6f 00   n.t.m.o.
> 00c8: 64 00 65 00 6c 00 2e 00   d.e.l...
> 00d0: 77 00 69 00 6e 00 33 00   w.i.n.3.
> 00d8: 32 00 20 00 4e 00 49 00   2. .N.I.
> 00e0: 4c 00 0d 00 0a 00         L.....
>
> Paul.
>
>
>
> > -----Original Message-----
> > From: xap_automation@xxxxxxx
> > [mailto:xap_automation@xxxxxxx] On
Behalf Of Kevin Hawkins
> > Sent: 10 June 2007 19:55
> > To: xap_automation@xxxxxxx
> > Subject: Re: [xap_automation] xAP hub 2 errors
> >
> > Yes - it's dying on me too - I'll try this fix - thanks Max
> >
> > I'm seeing this in Viewer too - but it's likely  me causing the
error
> > with the xAP C-Bus HomeVision gateway using xAP v1.3.   I can't
quite
> > determine which message causes it...
> > "There are insufficient subaddress parameters in the Address
value
> > Parameter name: nth Actual value was 1."
> >
> > K
> >
> >
> > max barker wrote:
> > > I had an issue with the xFx v2 service hub, but my post to
the
> group
> > > disappeared and I managed to fix it on my own. I didn't get
any
> > errors
> > > during instalation, but like you, the service would stop
running.
> > What
> > > seemed to fix it was runnning the GUI v2 hub, then
restarting the
> > > service hub. Since then the hub has started of its own
accord and
> run
> > > with no problems.
> > > I've since installed the service hub on three other XP
machines
> with
> > > the same problem and solution.
> > >
> > > Max
> > >
> > > On 10/06/07, *Paul Gale* < groups2@xxxxxxx
> > > <mailto:groups2@xxxxxxx>> wrote:
> >
> >
> >
> >
> > Yahoo! Groups Links
> >
> >
> >
>
>
>