[Message Prev][Message
Next][Thread Prev][Thread Next][Message
Index][Thread Index]
Re: BSC Protocol question
- Subject: Re: BSC Protocol question
- From: "mx773406" <mx773406@xxxxxxxxx>
- Date: Sat, 12 Apr 2008 20:35:58 -0000
Hi Kevin -
The Ocelot can receive and send, but the SECU16-IR only does transmit.
Thanks for the pointer about v1.3. I went to the files section here
and downloaded a document on v1.3. I'll look that over.
I appreciate your help
Matt
--- In xap_automation@xxxxxxx, Kevin Hawkins
<yahoogroupskh@...> wrote:
>
> Hi Matt,
>
> Nice application - I have a Leopard - and I almost got an Ocelot
on
> eBay last week. IIRC the range of products only supports IR TX and
> not IR RX - am I right ?
>
> Re the BSC questions - yes you're correct in your interpretation.
> You can name the IR signals should you wish as well eg
> Module.Point.Lounge.AIWA.Vol_Up should you wish - although it may
> not serve any useful purpose.
>
> Re the restriction to two hex digits (254 devices as 00 and FF are
> reserved) - this was a limitation in xAP v1.2. There is an updated
> version of xAP (v1.3) that increases this to eliminate this
restriction
> . Have a search in the posts here and also the xAP Developer list.
>
> Essentially you change the xAP header ver= parameter to ver=13 and
the
> UID has a new format
> UID=NN.AAAA:SSSS where
> NN=network
> AA=application address (must be unique)
> SS= sub address
>
> The three segments can be any even number of hex digits so you can
have
> 4 digits (or more) for your sub addresses :-). You will probably use
> the format above.
>
> In the BSC schema your ID= parameter has to match in the number of
> digits so typically something like
> ID=00F2 or
> ID=016E
>
> Also just to clarify another change in xAP v1.3.
> The feature allowing you to include a target= parameter within message
> blocks has been deprecated.
>
> Any more Q's just ask away and I look forward to seeing the
application :-)
>
>
>
> Cheers Kevin
------------------------------------
xAP_Automation Main Index |
xAP_Automation Thread Index |
xAP_Automation Home |
Archives Home
|