Re: xAP Plugin for SqueezeCenter v2.2.1 released



It's a very useful app Kevin - and I have a few things I include this
way.

One aspect is that it leaves the tray icon present when Intranet
Launcher is running- whereas the other Intranet aware apps hide
themselves.   Would it be possible for it to disappear this way and be
accessible via an Intranet Launcher 'exit/show' menu like say xAP Blue
has  (although actually I can't get Blue to 'exit' the 'show' does work).

K

Kevin T wrote:
> Hi
>
> Unless Edward was to implement the full fuctionality of the web
> interface as provided by xAPIntranet.ocx, I think this might be a bit
> one way, that is squeezecenter would appear in the icon menu along the
> top of a xAPIntranet application, but once you got to squeezecenter
> you would not have the means in that web interface to access any other
> xAPIntranet applications. Of course It would allow the Intranet
> Launcher to work OK but it would be a bit "half of a job" if
only the
> Intranet Launcher worked properly
>
> If I may suggest as an alternative, you can embed squeezecenter web
> interface in the "Generic Intranet Wrapper" which I  have
made
> available on James mi4 site. This should give you everything you need
> as its function is to allow any web interface to be embedded in a
> xAPIntranet system. I have done this successfully with earlier
> versions of this squeezebox web interface.
>
> I have a couple of unpublished, updated versions of the Wrapper
> available as well if you would care to try them out
>
> Kevin T
> www.netcomp.biz <http://www.netcomp.biz>
>
>
>
>
> On 21/10/2008, *max barker* <vworpi@xxxxxxx
> <mailto:vworpi@xxxxxxx>> wrote:
>
>     http://mi4.biz/modules.php?name=Content&pa=showpage&pid=48
>     <http://mi4.biz/modules.php?name=Content&pa=showpage&pid=48>
>
>     web.service messages to announce the location of the Squeezecenter
>     web interface.
>
>
>
>     2008/10/21 Edward Pearson <edward.mailgroup@xxxxxxx
>     <mailto:edward.mailgroup@xxxxxxx>>
>
>         Me no understand. "intranet messages"?
>
>
>
>         *From:* xap_automation@xxxxxxx
>         <mailto:xap_automation@xxxxxxx>
>         [mailto:xap_automation@xxxxxxx
>         <mailto:xap_automation@xxxxxxx>]
*On Behalf Of *max barker
>         *Sent:* 18 October 2008 15:03
>
>         *To:* xap_automation@xxxxxxx
>         <mailto:xap_automation@xxxxxxx>
>         *Subject:* Re: [xap_automation] xAP Plugin for SqueezeCenter
>         v2.2.1 released
>
>
>
>         Any chance you can add support for xAP intranet messages?
>
>         Max
>
>         2008/10/15 Edward Pearson <edward.mailgroup@xxxxxxx
>         <mailto:edward.mailgroup@xxxxxxx>>
>
>         Hmmm ? I thought State was mandatory :-/
>
>
>
>         There's another, closely related, bug in v2.2.1 ? the plugin
>         won't respond to an absolute level
>
>         Level=50/100 works
>
>         Level=50 doesn't work.
>
>
>
>         Fixes for both these will be in v.2.2.2 ? later this week.
>
>
>
>         Edward
>
>
>
>         *From:* xap_automation@xxxxxxx
>         <mailto:xap_automation@xxxxxxx>
>         [mailto:xap_automation@xxxxxxx
>         <mailto:xap_automation@xxxxxxx>]
*On Behalf Of *Kevin
>         Hawkins
>         *Sent:* 14 October 2008 00:17
>
>
>         *To:* xap_automation@xxxxxxx
>         <mailto:xap_automation@xxxxxxx>
>
>         *Subject:* Re: [xap_automation] xAP Plugin for SqueezeCenter
>         v2.2.1 released
>
>
>
>         Funny - we were just chatting about that last night...
>
>
>         A BSC node should accept a cmd message with any or all
>         (including none)
>         of the parameters and action them accordingly. However the ID=
>         parameter
>         is mandatory and must always be included - (even if it is
ID=*)
>
>         K
>
>         max barker wrote:
>         > I'm not sure what the BSC spec is for this, but the
connector
>         doesn't
>         > apply levels from a xapbsc.cmd message if a state isn't
>         present. eg
>         > from opn-max:
>         >
>         > xap-header
>         > {
>         > v=12
>         > hop=1
>         > uid=FF017700
>         > class=xAPBSC.cmd
>         > source=opnode.opnmax.xapmaster
>         > target=ersp.SlimServer.Server:kitchenSqueeze
>         > }
>         > output.state.1
>         > {
>         > id=*
>         > level=75/100
>         > }
>         >
>         > Add a state=on or off in there and the level changes
accordingly.
>         >
>         > Max
>         >
>         > 2008/10/2 Edward Pearson <edward.mailgroup@xxxxxxx
>         <mailto:edward.mailgroup%40blueyonder.co.uk>
>         > <mailto:edward.mailgroup@xxxxxxx
>         <mailto:edward.mailgroup%40blueyonder.co.uk>>>
>         >
>         > I've just released an update to the xAP SqueezeCenter
plug-in.
>         >
>         > Change log (v2.2.1):
>         > Fixed case where Now.Playing shows wrong song data after
player
>         > sync/unsync.
>         > Fixed issue where BSC ID=nnnn parameter being parsed
>         incorrectly in
>         > xAPBSC.Cmd messages.
>         > Added xAPBSC.Cmd state=toggle.
>         > Improved BSC Event/Info selection/timing.
>         > Send xAPBSC.Event when DisplayText changes (maybe
off-spec but
>         > useful).
>         > Send xAPBSC.Event on power up due to xAP-Audio.Transport
command.
>         > Added alarm notifications to xAP-Audio.Schedule.Event
messages.
>         > Added simple alarm control (enable/disable all) via
>         > xAP-Audio.Schedule.
>         > Removed last dependencies on legacy command execution
(which is
>         > broken in
>         > 7.2.1 23353).
>         > Harmonised log4perl logger categories and added to
documentation
>         > to user
>         > manual.
>         >
>         > The most recent officially supported SqueezeCenter
release
>         remains 7.2
>         > though this plug-in release does address the significant
>         > incompatibility
>         > with 7.2.1 (nightly up to 23353) that broke handling
incoming
>         > commands.
>         > Raised a bugzilla bug (9620) on that one.
>         >
>         > Plug-in download via www.erspearson.com/xAP
>         <http://www.erspearson.com/xAP>
>         > <http://www.erspearson.com/xAP
<http://www.erspearson.com/xAP>>
>         >
>         > Edward
>         > ersp - design, London
>         >
>         >
>         >
>         >
>         >
>         > ------------------------------------
>         >
>         > Yahoo! Groups Links
>         >
>         >
>         > (Yahoo! ID required)
>         >
>         > mailto:xap_automation-fullfeatured@xxxxxxx
>         <mailto:xap_automation-fullfeatured%40yahoogroups.com>
>         > <mailto:xap_automation-fullfeatured@xxxxxxx
>         <mailto:xap_automation-fullfeatured%40yahoogroups.com>>
>         >
>         >
>         >
>         >
>         >
>
>
>
>
>
>


------------------------------------


xAP_Automation Main Index | xAP_Automation Thread Index | xAP_Automation Home | Archives Home

Comments to the Webmaster are always welcomed, please use this contact form . Note that as this site is a mailing list archive, the Webmaster has no control over the contents of the messages. Comments about message content should be directed to the relevant mailing list.