It's a very useful app Kevin - and I have a few things I include this
way.
One aspect is that it leaves the tray icon present when Intranet
Launcher is running- whereas the other Intranet aware apps hide
themselves. Would it be possible for it to disappear this way and be
accessible via an Intranet Launcher 'exit/show' menu like say xAP Blue
has (although actually I can't get Blue to 'exit' the 'show' does work).
K
Kevin T wrote:
> Hi
>
> Unless Edward was to implement the full fuctionality of the web
> interface as provided by xAPIntranet.ocx, I think this might be a bit
> one way, that is squeezecenter would appear in the icon menu along the
> top of a xAPIntranet application, but once you got to squeezecenter
> you would not have the means in that web interface to access any other
> xAPIntranet applications. Of course It would allow the Intranet
> Launcher to work OK but it would be a bit "half of a job" if
only the
> Intranet Launcher worked properly
>
> If I may suggest as an alternative, you can embed squeezecenter web
> interface in the "Generic Intranet Wrapper" which I have
made
> available on James mi4 site. This should give you everything you need
> as its function is to allow any web interface to be embedded in a
> xAPIntranet system. I have done this successfully with earlier
> versions of this squeezebox web interface.
>
> I have a couple of unpublished, updated versions of the Wrapper
> available as well if you would care to try them out
>
> Kevin T
> www.netcomp.biz <http://www.netcomp.biz>
>
>
>
>
> On 21/10/2008, *max barker* <vworpi@xxxxxxx
> <mailto:vworpi@xxxxxxx>> wrote:
>
> http://mi4.biz/modules.php?name=Content&pa=showpage&pid=48
> <http://mi4.biz/modules.php?name=Content&pa=showpage&pid=48>
>
> web.service messages to announce the location of the Squeezecenter
> web interface.
>
>
>
> 2008/10/21 Edward Pearson <edward.mailgroup@xxxxxxx
> <mailto:edward.mailgroup@xxxxxxx>>
>
> Me no understand. "intranet messages"?
>
>
>
> *From:* xap_automation@xxxxxxx
> <mailto:xap_automation@xxxxxxx>
> [mailto:xap_automation@xxxxxxx
> <mailto:xap_automation@xxxxxxx>]
*On Behalf Of *max barker
> *Sent:* 18 October 2008 15:03
>
> *To:* xap_automation@xxxxxxx
> <mailto:xap_automation@xxxxxxx>
> *Subject:* Re: [xap_automation] xAP Plugin for SqueezeCenter
> v2.2.1 released
>
>
>
> Any chance you can add support for xAP intranet messages?
>
> Max
>
> 2008/10/15 Edward Pearson <edward.mailgroup@xxxxxxx
> <mailto:edward.mailgroup@xxxxxxx>>
>
> Hmmm ? I thought State was mandatory :-/
>
>
>
> There's another, closely related, bug in v2.2.1 ? the plugin
> won't respond to an absolute level
>
> Level=50/100 works
>
> Level=50 doesn't work.
>
>
>
> Fixes for both these will be in v.2.2.2 ? later this week.
>
>
>
> Edward
>
>
>
> *From:* xap_automation@xxxxxxx
> <mailto:xap_automation@xxxxxxx>
> [mailto:xap_automation@xxxxxxx
> <mailto:xap_automation@xxxxxxx>]
*On Behalf Of *Kevin
> Hawkins
> *Sent:* 14 October 2008 00:17
>
>
> *To:* xap_automation@xxxxxxx
> <mailto:xap_automation@xxxxxxx>
>
> *Subject:* Re: [xap_automation] xAP Plugin for SqueezeCenter
> v2.2.1 released
>
>
>
> Funny - we were just chatting about that last night...
>
>
> A BSC node should accept a cmd message with any or all
> (including none)
> of the parameters and action them accordingly. However the ID=
> parameter
> is mandatory and must always be included - (even if it is
ID=*)
>
> K
>
> max barker wrote:
> > I'm not sure what the BSC spec is for this, but the
connector
> doesn't
> > apply levels from a xapbsc.cmd message if a state isn't
> present. eg
> > from opn-max:
> >
> > xap-header
> > {
> > v=12
> > hop=1
> > uid=FF017700
> > class=xAPBSC.cmd
> > source=opnode.opnmax.xapmaster
> > target=ersp.SlimServer.Server:kitchenSqueeze
> > }
> > output.state.1
> > {
> > id=*
> > level=75/100
> > }
> >
> > Add a state=on or off in there and the level changes
accordingly.
> >
> > Max
> >
> > 2008/10/2 Edward Pearson <edward.mailgroup@xxxxxxx
> <mailto:edward.mailgroup%40blueyonder.co.uk>
> > <mailto:edward.mailgroup@xxxxxxx
> <mailto:edward.mailgroup%40blueyonder.co.uk>>>
> >
> > I've just released an update to the xAP SqueezeCenter
plug-in.
> >
> > Change log (v2.2.1):
> > Fixed case where Now.Playing shows wrong song data after
player
> > sync/unsync.
> > Fixed issue where BSC ID=nnnn parameter being parsed
> incorrectly in
> > xAPBSC.Cmd messages.
> > Added xAPBSC.Cmd state=toggle.
> > Improved BSC Event/Info selection/timing.
> > Send xAPBSC.Event when DisplayText changes (maybe
off-spec but
> > useful).
> > Send xAPBSC.Event on power up due to xAP-Audio.Transport
command.
> > Added alarm notifications to xAP-Audio.Schedule.Event
messages.
> > Added simple alarm control (enable/disable all) via
> > xAP-Audio.Schedule.
> > Removed last dependencies on legacy command execution
(which is
> > broken in
> > 7.2.1 23353).
> > Harmonised log4perl logger categories and added to
documentation
> > to user
> > manual.
> >
> > The most recent officially supported SqueezeCenter
release
> remains 7.2
> > though this plug-in release does address the significant
> > incompatibility
> > with 7.2.1 (nightly up to 23353) that broke handling
incoming
> > commands.
> > Raised a bugzilla bug (9620) on that one.
> >
> > Plug-in download via www.erspearson.com/xAP
> <http://www.erspearson.com/xAP>
> > <http://www.erspearson.com/xAP
<http://www.erspearson.com/xAP>>
> >
> > Edward
> > ersp - design, London
> >
> >
> >
> >
> >
> > ------------------------------------
> >
> > Yahoo! Groups Links
> >
> >
> > (Yahoo! ID required)
> >
> > mailto:xap_automation-fullfeatured@xxxxxxx
> <mailto:xap_automation-fullfeatured%40yahoogroups.com>
> > <mailto:xap_automation-fullfeatured@xxxxxxx
> <mailto:xap_automation-fullfeatured%40yahoogroups.com>>
> >
> >
> >
> >
> >
>
>
>
>
>
>
------------------------------------
xAP_Automation Main Index |
xAP_Automation Thread Index |
xAP_Automation Home |
Archives Home
|