The UK Home Automation Archive

Archive Home
Group Home
Search Archive


Advanced Search

The UKHA-ARCHIVE IS CEASING OPERATIONS 31 DEC 2024


[Message Prev][Message Next][Thread Prev][Thread Next][Message Index][Thread Index]

RE: More homeseer level issues.


  • Subject: RE: More homeseer level issues.
  • From: "Ian Davidson" <ian@xxxxxxxxxxxxxxxx>
  • Date: Sun, 5 Aug 2007 08:04:13 +0100

Hi Kevin,

Thanks for checking this, I'll wait a while and see if anyone has the
answer I've got plenty other bits to be doing.

I have another question which you may be able to answer.

My device works fine and can be controlled via HS. When it receives the
".cmd" msg it actions it and also sends out a ".event"
msg. Up until now
the .event msg always just matched the ".cmd" msg from HS. I have
now
added local control for the device. When the local control is used to
change the state of the device again a ".event" msg is sent.
However the
status shown in HS remains the same and is not updated. I have refreshed
the screen etc but no change. I'm quite certain that status updates
would have been written into the plug-in so I'm presuming I have also to
set another part of HS up to achieve this?

When locally triggered this is a ".event" msg generated.

xap-header
{
v=12
hop=1
uid=FF341201
class=xAPBSC.event
source=gforce9.test.study:Virtual.1
}
output.state
{
state=On
level=100
}

The device was off and then locally turned on. HS still shows the device
as switched off.

Thanks

Ian D


-----Original Message-----
From: xAP_developer@xxxxxxx
[mailto:xAP_developer@xxxxxxx] On
Behalf Of Kevin Hawkins
Sent: 04 August 2007 16:31
To: Ian
Subject: Re: [xAP_developer] More homeseer level issues.

Paradoxically - If I set the device to say 50% from the mcs plugin
(Level=50%) then my mcs device actually shows 52% in its status display
and my 'James' based device updates and shows 50%  .  If I set the
device from J's plugin to 50% (Level=52/100) then the device shows as
52% in J's plugin and 50% in mcs's status display.     I know the mcs
one is based on HV's internal state (not updated from the xAP event
message) and J's is updated from the event message.

K

Kevin Hawkins wrote:
> I hadn't used HS for a while but have downloaded and installed it and
> I'm seeing the same Ian.  The xAPBSC.cmd issued by HS is slightly off
in
> its level  it seems ...   I wonder if its something to do with HS
being
> X10 based and X10 supporting just 16 levels (or is it 32) . Perhaps
the
> 'level' that is sent is recovered from an internal variable only
storing
> 16 levels or something.   I'll have to defer to James..
>
> I have also been playing with Michaels (mcs) new .Net plugin for HS2.
I
> tried it with that and it correctly sends 50%  (as a % not as 50/100
but
> that is not important - both are valid).   I have a couple of other
> issues with this plugin however so I cant recommend you use it just
> yet   You might get accurate and more dependable functionality from
his
> VB6 plugin though , although I'm sure James will be able to fix this
> issue fairly easy too - as it's so reproducable.
>
> K
>
>     Kevin
>
> Ian Davidson wrote:
>
>> Hi Kevin
>>
>> Yes the status column on the status page within homeseer.
>>
>> Using the pull down box on the same page to set a level to say 50%
for
>> an X10 device the status column says 50%. If I do the same for an
XAP
>> device it says 52% and the Xap message generated (cmd) also
contains
the
>> 52%. I had got devices set up with a level "out of
65535". Just in
case
>> this was an issue I deleted all the devices and re-detected the
Xap
>> devices and re-assigned new devices numbers with the level set for
"out
>> of 100". The error is still the same.
>>
>> The error is still there even when I disable my event messages.
>>
>> This is the xAPBSC.cmd message sent from homeseer when I used the
pull
>> down box and selected 50%.
>>
>> xap-header
>> {
>>     v=12
>>     hop=1
>>     uid=FF411100
>>     class=xAPBSC.cmd
>>     source=mi4.homeseer.sbs-server.Master
>>     target=gforce9.test.study:Virtual.1
>> }
>> output.state.1
>> {
>>     id=01
>>     level=52/100
>> }
>>
>> It seems as though this is something that happens as the device is
>> created as it happens straight away.
>>
>> Thanks
>>
>> Ian D
>>
>>
>> -----Original Message-----
>> From: xAP_developer@xxxxxxx
>> [mailto:xAP_developer@xxxxxxx] On
Behalf Of Kevin Hawkins
>> Sent: 03 August 2007 19:46
>> To: Ian
>> Subject: Re: [xAP_developer] More homeseer level issues.
>>
>> Hi Ian,
>>
>> You mean the value displayed in the status column Ian ?
>>
>> This value is calculated and updated by the returned .event
message
from
>>
>> your endpoint - could you post an example of the xAPBSC.cmd
message
that
>>
>> HS sends when you click the % setting and also the resulting
>> xAPBSC.event message from your device .
>>
>> What resolution is your device - ie how many discreet steps of
>> brightness ? Setting a 16 level device to say 60% could never work
for
>> example..
>>
>> 9/16 = 56.25%
>> 10/16 = 62.5 %
>>
>> Kevin
>>
>> Ian Davidson wrote:
>>
>>
>>> Hi
>>>
>>>
>>> As I have mention the missing messages and old values problem
is
fixed
>>>
>>>
>>
>>
>>> and xap messages appear every time now.
>>>
>>> One strange thing remaining is when setting the level on the
status
>>> screen most of the values are slightly out like this:
>>>
>>> Changed to Goes to
>>>
>>> 0 0
>>>
>>> 10 10
>>>
>>> 20 19
>>>
>>> 30 29
>>>
>>> 40 39
>>>
>>> 50 52
>>>
>>> 60 61
>>>
>>> 70 71
>>>
>>> 80 81
>>>
>>> 90 90
>>>
>>> 100 100
>>>
>>> Now I know it is only slightly out and a couple of percent of
>>> brightness wouldn't make a difference, however I am using the
BSC
>>> level value on different channels to perform different
functions.
One
>>> of the functions is a recall preset function i.e. level=10
recall
>>> preset 10. So if the level is out even by one it will recall
the
wrong
>>>
>>>
>>
>>
>>> preset. The non xap devices in HS function correctly it is
only the
>>> xap devices which show this effect.
>>>
>>> Thanks
>>>
>>> Ian D
>>>
>>>
>>>
>>>
>>
>>
>> Yahoo! Groups Links
>>
>>
>>
>>
>>
>>
>>
>>
>>
>>
>> Yahoo! Groups Links
>>
>>
>>
>>
>>
>>
>
>
>
>
> Yahoo! Groups Links
>
>
>
>
>





xAP_Development Main Index | xAP_Development Thread Index | xAP_Development Home | Archives Home