W800 Service Updated


  • Subject: W800 Service Updated
  • From: "Mal Lansell" <mlansell@xxxxxxxxxxxxxx>
  • Date: Fri, 17 Dec 2004 21:05:57 -0000



I've updated the W800RF32 service to handle messages from X10
security RF devices

Unfortunately, the security devices are intended to be used only with
their base stations, rather than as general X10 controls.  The
messages they send have no relation to any of the standard X10
functions.  Therefore, the service sends security messages using the
remote.basic schema (standard X10 RF commands are still sent using
X10.basic).

It uses two of the remote.basic message body elements -
keys=num1 (where num1 is the keycode sent by the device 0-255)
device=num2 (where num2 is the id of the security device 0-255)

This should be sufficient to distinguish between controllers, and to
use their commands to trigger determinators etc.

Mal