> I upgraded to 16A triacs but more inportantly used HI-SPEED CERAMIC
fuses.
> The fuses were actually more expensive than the triacs but I NEVER
blew a
> triac after that.
Way to go. since triac's tend to fail closed it is dificult to
explain to a user its the triac, the user just thinks you are talking
c...
Its also a lot easer to swap a expensive fuse than a cheap triac.
>
> The main reason for keeping the rating down is the cost of the
chokes. They
> will cost as much as the Relay+Triac+Opto. The higher the rating
the more
> the choke will cost. Also Isolated tab triacs >16A rating are VERY
> expensive.
>
> Some commercial controllers have the triac legs connected via
cageclamp
> terminal blocks. Self tapper into the heatsink. Triac change is a
two minute
> job involving 4 screws.
I can see in a comercial situation, but i dont think my mother - in -
law could swap a triac.
John