One other reason for the extra wire is that you can always add a second
switch to control another LD10. You also never know what self contained
modules may arrive in the future.

3core + Earth allows the following ...
RED - Live IN
YELLOW - Switched/Dimmed Live out
BLUE - Neutral IN
Earth - Earth.

or with 2 existing LD10's
RED - Live IN
YELLOW - Switch Control for first AD10
BLUE - Switch Control for second AD10
Earth - Earth.

Keith

www.diyha.co.uk
www.kat5.tv


-----Original Message-----
From: Tracey Gardner [mailto:tracey.gardner@xxxxxxx]
Sent: 06 July 2002 13:36
To: ukha_d@xxxxxxx Subject: [ukha_d] Cabling from switches to LD units


Thanks for the reply Graham.
Can you elaborate on what situations I'd need the neutral appearing at the
switch, ie how do AD10s differ from the normal X10 dimmer unit, which is an
LD?

Tracey

> For momentary switches T & E is fine, but some people may have used
> three core and earth because of future enhancement, for example if you
> wanted to move to AD10 units in the future then you would been the
> neutral. Of course someone who had total disregard for electrical
> standards could suggest that the earth in T&E might be used as a neutral
> in future, but I couldn't possibly recommend that ;-)
>




For more information: http://www.automatedhome.co.uk
Post message: ukha_d@xxxxxxx Subscribe:  ukha_d-subscribe@xxxxxxx Unsubscribe:  ukha_d-unsubscribe@xxxxxxx List owner:  ukha_d-owner@xxxxxxx
Your use of Yahoo! Groups is subject to http://docs.yahoo.com/info/terms/



For more information: http://www.automatedhome.co.uk
Post message: ukha_d@xxxxxxx
Subscribe:  ukha_d-subscribe@xxxxxxx
Unsubscribe:  ukha_d-unsubscribe@xxxxxxx
List owner:  ukha_d-owner@xxxxxxx

Your use of Yahoo! Groups is subject to the Yahoo! Terms of Service.

Home | Main Index | Thread Index

Comments to the Webmaster are always welcomed, please use this contact form . Note that as this site is a mailing list archive, the Webmaster has no control over the contents of the messages. Comments about message content should be directed to the relevant mailing list.