The UK Home Automation Archive

Archive Home
Group Home
Search Archive


Advanced Search

The UKHA-ARCHIVE IS CEASING OPERATIONS 31 DEC 2024


[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

RE: Mv1000 cont...



I have now reset back to the factory defaults, re configured and still
nothing.

I tried a cross over cable to a stand alone PC that is on the same subnet
mask etc but still nothing.

I have tried different cat5 cables, nothing...

I think I have bought a duff Mv1000....bugger...

Good whilst it lasted.....

B.

-----Original Message-----
From: Brian G. Reynolds
Sent: 21 August 2003 18:40
To: Ukha_D (E-mail)
Subject: RE: [ukha_d] Mv1000 cont...


I could try that......if I could get the thing to work at all now!

I think I might use a crossover cable and connect it straight to a PC and
see if that works....

Thanks anyway....still trying...

B.

PS sorry but can not email you direct, have to send to the group...


-----Original Message-----
From: Paul Smith [mailto:wheelbarrowhandle@xxxxxxx]
Sent: 21 August 2003 07:52
To: Brian G. Reynolds
Subject: RE: [ukha_d] Mv1000 cont...


Hi Brian,


It looks like the mv1000 is redetecting cameras every 60 seconds.
This maybe why you can't see them.


I think it's on the camera page that you can set the re detect option. Try
changing it to a much bigger figure. Or for now disable it.


Regards,


Paul


-----Original Message-----
From: Brian G. Reynolds [mailto:brian.g.reynolds@xxxxxxx]
Sent: 20 August 2003 20:28
To: ukha_d@xxxxxxx
Subject: RE: [ukha_d] Mv1000 cont...

Ignore last posting, the direct posting was returned direct back to me!!!!

that is the third NTL email address I can not email too!

So I will paste the code below, my apologies to other users.

B.




System page at p0003b000 (vff910000)
Raminfo
addr:0003c000 size:0005fc00 addr:00100000 size:00700000
Boxinfo
cpu:000001e6 fpu:000001e7 cpu_flags:00000075 cpu_speed:00001634
ram_size:0079bc00 hw_flags:00000040 cpu_id:AMD 486DX4 F4M8S4
real_addr:ff800000
Displayinfo
primary:0000 secondary:0000 cg_table: 00000000 00000000 00000000
00000000 00000000 00000000 00000000 00000000 00000000 00000000
Diskinfo
ndisks:0000
0000)  ncyl:0000 nhead:0000 nsect:0000
0001)  ncyl:0000 nhead:0000 nsect:0000
0002)  ncyl:0000 nhead:0000 nsect:0000
0003)  ncyl:0000 nhead:0000 nsect:0000
Qtime
sec:3eab3cd1 cycles_per_sec:001234de clk8254:31f451f1
Osinfo
nodename:node1 nodenum:0001
Bootinfo
user_sys_ptr:ff910000 ker_sys_ptr:ff911000 sys_size:00000c70
image_addr:00006000 image_size:00035000 dir_addr:00006000
args_addr:00000000
kern_addr:ff920000 kern_size:0001d440 user_addr:00400000
user_size:bfc00000
kstack_addr:ffc00000 mmgr_addr:c0000000 mmgr_size:3f800000
user_addr_end:00bfffff user_align:00400000

Devm.tx486: Mv-Engine FFS Device driver (c) Active Imaging (UK) Ltd.
Devm.tx486: V2.11 (Compiled on May 07 1998 @ 14:36:36)

Retrying open utility semaphoreMqueue handler running.
OK

Pty handler running.
Serial handler running.
Aug 20 20:00:19  syslogd: restart
























MV1000 (Rev 2.10)
HIT ANY KEY WITHIN 10 SECONDS TO TELL ME YOU'RE THERE:

Ok, byebye

Aug 20 20:00:36 nto Mv1000: WDOG:Enabling watchdog
Aug 20 20:00:38 nto Mv1000: HTTPD:Starting about thread
Aug 20 20:00:38 nto Mv1000: ACQD:Detecting cameras
Aug 20 20:00:39 nto Mv1000: IFACE:Mv1000 Ethernet
setting route to 192.168.1.3
Aug 20 20:00:41 nto Mv1000: ACQD:Camera detected on channel 1
Aug 20 20:00:44 nto Mv1000: ACQD:Camera detected on channel 2
Aug 20 20:00:47 nto Mv1000: ACQD:No camera detected on channel 3
Aug 20 20:00:50 nto Mv1000: ACQD:No camera detected on channel 4
Aug 20 20:00:53 nto Mv1000: ACQD:No camera detected on channel 5
Aug 20 20:00:56 nto Mv1000: ACQD:No camera detected on channel 6
Aug 20 20:00:56 nto Mv1000: ACQD:Complete
Aug 20 20:00:56 nto Mv1000: ACQD:Loading configuration
Aug 20 20:01:01 nto Mv1000: ACQD:Complete
Aug 20 20:01:01 nto Mv1000: HTTPD:Waiting to accept connection
Aug 20 20:01:38 nto Mv1000: ACQD:Camera redetected on channel  1
Aug 20 20:01:38 nto Mv1000: ACQD:Camera redetected on channel  2
Aug 20 20:02:38 nto Mv1000: ACQD:Camera redetected on channel  1
Aug 20 20:02:38 nto Mv1000: ACQD:Camera redetected on channel  2


** UKHA2004 BE THERE! ** - start planning now.

http://www.automatedhome.co.uk
Post message: ukha_d@xxxxxxx
Subscribe:  ukha_d-subscribe@xxxxxxx
Unsubscribe:  ukha_d-unsubscribe@xxxxxxx
List owner:  ukha_d-owner@xxxxxxx

Your use of Yahoo! Groups is subject to http://docs.yahoo.com/info/terms/






** UKHA2004 BE THERE! ** - start planning now.

http://www.automatedhome.co.uk
Post message: ukha_d@xxxxxxx
Subscribe:  ukha_d-subscribe@xxxxxxx
Unsubscribe:  ukha_d-unsubscribe@xxxxxxx
List owner:  ukha_d-owner@xxxxxxx

Your use of Yahoo! Groups is subject to http://docs.yahoo.com/info/terms/




Home | Main Index | Thread Index

Comments to the Webmaster are always welcomed, please use this contact form . Note that as this site is a mailing list archive, the Webmaster has no control over the contents of the messages. Comments about message content should be directed to the relevant mailing list.