[Message Prev][Message
Next][Thread Prev][Thread Next][Message
Index][Thread Index]
Re: Plasma cabling requirement
- Subject: Re: Plasma cabling requirement
- From: "Chris White" <cmw@xxxxxxxxxxxxxxx>
- Date: Thu, 30 Mar 2006 08:14:01 -0000
Hi Dean,
Basic HD signals without HDCP can be carried over a Component
multicore, or mini coax.
It is when you get up to HDMI connections that do carry HDCP that we
have a problem.
The other way to look at it is to offer 2 RJ45 / Cat5e connections
between the equipment room or corner and the Plasma as there are boxes
that will pass full HDCP'ed Hi Def over 2 sets of Cat5e.
I would also, if poss, allow for an additional network point (if being
installed) at the plasma for IPTV, streamed services or even a more
basic AV over Cat5e matrix.
Chat later
Chris
--- In ukha_d@xxxxxxx, "Dean Barrett" <dean@...> wrote:
>
>
>
> I've just been asked to pre-wire some houses for wall mounted
Plasma's.
>
> This is usually carried out for them by an AV guy - he wants ducts
etc., and
> they dont, as they have to batten walls out to cater for his 32mm
ducts.
>
> What sensible cabling requirement would be acceptable for a plasma -
i'm
> thinking 1 x CT100, 1 x Power & 1 x Multicore Coax thing - dont
know
> technical term, but it has five/six small colour coded coax's in it
which i
> believe are used for the component signals if a seperate box is used
for
> Plasma.
>
> I havent look at HD at all, and dont know if there's a cable (no
plugs) that
> could be built in wall and plastered over.
>
> Any suggestions appreciated.
>
> This is a volume builder doing a site of 50 units, so nothing fancy is
> allowed.
>
>
>
>
>
> Dean.
>
>
>
>
> [Non-text portions of this message have been removed]
>
UKHA_D Main Index |
UKHA_D Thread Index |
UKHA_D Home |