Rob
I don't believe you can switch off individual node events.
The following command will set the counter to 0. You can actually set to
any acceptable value.

xap-header
{
v=12
hop=1
uid=FF411100
class=netiom.cmd
source=mi4.homeseer.dpjukebox.Master
target=phaedrus.netiom.location
}
counters.state
{
counter.1=0
}
I haven't seen the problem with the counter going negative but it
certainly sounds like a bug to me. I can see how it might happen though.
I am sure that Roy will fix this.

BR
David

-----Original Message-----
From: xap_automation@xxxxxxx
[mailto:xap_automation@xxxxxxx] On
Behalf Of Robert Kearns
Sent: 01 July 2005 20:01
To: xap_automation@xxxxxxx
Subject: [xap_automation] Netiom-xAP

Hi,

I'm using a netiom-xAP to monitor the flashing light on my electricity
meter and checking the counter every five minutes to get the reading.
As I don't require the events from the input is it possible to disable
them?

Also I haven't been able to workout the xAP message to reset a
counter. Could someone post an example?

Lastly, I've noticed that when a counter reaches the limit of 32767 it
goes negative. I assume this is a bug?

Thanks
Rob