[Message Prev][Message
Next][Thread Prev][Thread Next][Message
Index][Thread Index]
Re: Re: xAP Stopped Working
Hi Kevin,
Point taken about the hub.. using the new one now and have written a
script to make sure it loads before Homeseer and Redrat.
I've only got one network adapter in the PC and a look in network
connections confirm this.
A viewer running on a different PC sees xAP messages from the 2K3 PC !
But interesting enough, no messages from the Hub.. at least nothing on
port 3639!
Very strange as this is the new hub running.
Kevin Hawkins wrote:
>
>
> I too would recommend staying with a separate service based hub - but
> ensure it is the very first xAP (service) that loads, before RedRat
and HS.
>
> Have you by any chance got two network adaptors active in this machine
> now ? Look in Network Connections which I think is the same on 2K3 -
> this could cause xAP to bind to the wrong one.
>
> If you run xFX Viewer on a different PC do you see xAP messages from
the
> 2K3 machine and if so what ports do they show they are using in their
> heartbeats ? The hub should be operational on port 3639. Applications
> being deaf is a classic sysmptom of the xAP hub not running - but all
> apps can still send xAP messages.
>
> K
>
> marcrfuller wrote:
> >
> >
> > Hi Edward,
> >
> > Many thanks for the reply. I'm using Windows Server 2003 so
there is
> > no firewall running. I've tried the latest hub... no joy. No
messages
> > at all!
> >
> > Any other ideas?
> >
> > Many Thanks
> >
> > Marc
> >
> > --- In xap_automation@xxxxxxx
> <mailto:xap_automation%40yahoogroups.com>
> > <mailto:xap_automation%40yahoogroups.com>,
"Edward Pearson"
> > <edward.mailgroup@...> wrote:
> > >
> > > First thought would be to check your firewall settings,
they may
> > have gotten
> > > mixed up across the IP config change.
> > >
> > >
> > >
> > > Also, I think it'd be better to install a newer, dedicated
hub
> > rather than
> > > use the one in the RedRat connector.
> > >
> > > http://www.erspearson.com/xAP/xFx/hubs_main.htm
> <http://www.erspearson.com/xAP/xFx/hubs_main.htm>
> > <http://www.erspearson.com/xAP/xFx/hubs_main.htm
> <http://www.erspearson.com/xAP/xFx/hubs_main.htm>>
> > >
> > >
> > >
> > >
> > >
> > > From: xap_automation@xxxxxxx
> <mailto:xap_automation%40yahoogroups.com>
> > <mailto:xap_automation%40yahoogroups.com>
> > [mailto:xap_automation@xxxxxxx
> <mailto:xap_automation%40yahoogroups.com>
> > <mailto:xap_automation%40yahoogroups.com>]
> > > On Behalf Of marcrfuller
> > > Sent: 21 July 2009 09:17
> > > To: xap_automation@xxxxxxx
> <mailto:xap_automation%40yahoogroups.com>
> > <mailto:xap_automation%40yahoogroups.com>
> > > Subject: [xap_automation] xAP Stopped Working
> > >
> > >
> > >
> > >
> > >
> > > Hey Guys,
> > >
> > > I wonder if anyone can help. I am having problems with xAP
all of a
> > sudden
> > > and have no idea on how to get it working again.
> > >
> > > I have my server, which runs Homeseer & a Redrat.
> > >
> > > The Redrat xAP program is loaded first, as this also acts
as a hub.
> Then
> > > once loaded, Homeseer with the xAP conduit is run. IR
commands are
> > then send
> > > from Homeseer to the Redrat via xAP. It's all on the same
PC.
> > >
> > > Now this normally works beautifully, but for some reason it
has stopped
> > > working. If I load on xAP viewer, I am getting NO xAP
messages at
> > all... not
> > > even a heartbeat. xAP messages sent do not get received by
> > anything.. not
> > > Homeseer, not the RedRat, and not the viewer.
> > >
> > > The only thing I can think of that MAY have caused this is
the
> server IP
> > > address. It was recently accidentally changed to DHCP and
spend two
> days
> > > with a different IP address. I've since set it back to
static. Could
> > this
> > > somehow cause the problems?
> > >
> > > It's as if xAP is unable to loop back to the local PC?!?!
> > >
> > > Any help appreciated.
> > >
> >
> >
>
>
------------------------------------
xAP_Automation Main Index |
xAP_Automation Thread Index |
xAP_Automation Home |
Archives Home
|