Re: Re: xAP Stopped Working



OK, getting somewhere. The Redrat hub never gave me any errors.

Once I installed the new hub, I had assumed it was working, but didn't
notice this little error...

"Failed to bind receive socket to 172.16.xx.xx:3639
(AccessDenied)"

What !! Why the hell would I be getting an access denied?

Any help appreciated.

Marc

Marc Fuller wrote:
>
>
> Hi Kevin,
>
> Point taken about the hub.. using the new one now and have written a
> script to make sure it loads before Homeseer and Redrat.
>
> I've only got one network adapter in the PC and a look in network
> connections confirm this.
>
> A viewer running on a different PC sees xAP messages from the 2K3 PC !
> But interesting enough, no messages from the Hub.. at least nothing on
> port 3639!
>
> Very strange as this is the new hub running.
>
> Kevin Hawkins wrote:
>  >
>  >
>  > I too would recommend staying with a separate service based hub
- but
>  > ensure it is the very first xAP (service) that loads, before
RedRat
> and HS.
>  >
>  > Have you by any chance got two network adaptors active in this
machine
>  > now ? Look in Network Connections which I think is the same on
2K3 -
>  > this could cause xAP to bind to the wrong one.
>  >
>  > If you run xFX Viewer on a different PC do you see xAP messages
from the
>  > 2K3 machine and if so what ports do they show they are using in
their
>  > heartbeats ? The hub should be operational on port 3639.
Applications
>  > being deaf is a classic sysmptom of the xAP hub not running -
but all
>  > apps can still send xAP messages.
>  >
>  > K
>  >
>  > marcrfuller wrote:
>  > >
>  > >
>  > > Hi Edward,
>  > >
>  > > Many thanks for the reply. I'm using Windows Server 2003 so
there is
>  > > no firewall running. I've tried the latest hub... no joy.
No messages
>  > > at all!
>  > >
>  > > Any other ideas?
>  > >
>  > > Many Thanks
>  > >
>  > > Marc
>  > >
>  > > --- In xap_automation@xxxxxxx
> <mailto:xap_automation%40yahoogroups.com>
>  > <mailto:xap_automation%40yahoogroups.com>
>  > > <mailto:xap_automation%40yahoogroups.com>,
"Edward Pearson"
>  > > <edward.mailgroup@...> wrote:
>  > > >
>  > > > First thought would be to check your firewall
settings, they may
>  > > have gotten
>  > > > mixed up across the IP config change.
>  > > >
>  > > >
>  > > >
>  > > > Also, I think it'd be better to install a newer,
dedicated hub
>  > > rather than
>  > > > use the one in the RedRat connector.
>  > > >
>  > > > http://www.erspearson.com/xAP/xFx/hubs_main.htm
> <http://www.erspearson.com/xAP/xFx/hubs_main.htm>
>  > <http://www.erspearson.com/xAP/xFx/hubs_main.htm
> <http://www.erspearson.com/xAP/xFx/hubs_main.htm>>
>  > > <http://www.erspearson.com/xAP/xFx/hubs_main.htm
> <http://www.erspearson.com/xAP/xFx/hubs_main.htm>
>  > <http://www.erspearson.com/xAP/xFx/hubs_main.htm
> <http://www.erspearson.com/xAP/xFx/hubs_main.htm>>>
>  > > >
>  > > >
>  > > >
>  > > >
>  > > >
>  > > > From: xap_automation@xxxxxxx
> <mailto:xap_automation%40yahoogroups.com>
>  > <mailto:xap_automation%40yahoogroups.com>
>  > > <mailto:xap_automation%40yahoogroups.com>
>  > > [mailto:xap_automation@xxxxxxx
> <mailto:xap_automation%40yahoogroups.com>
>  > <mailto:xap_automation%40yahoogroups.com>
>  > > <mailto:xap_automation%40yahoogroups.com>]
>  > > > On Behalf Of marcrfuller
>  > > > Sent: 21 July 2009 09:17
>  > > > To: xap_automation@xxxxxxx
> <mailto:xap_automation%40yahoogroups.com>
>  > <mailto:xap_automation%40yahoogroups.com>
>  > > <mailto:xap_automation%40yahoogroups.com>
>  > > > Subject: [xap_automation] xAP Stopped Working
>  > > >
>  > > >
>  > > >
>  > > >
>  > > >
>  > > > Hey Guys,
>  > > >
>  > > > I wonder if anyone can help. I am having problems with
xAP all of a
>  > > sudden
>  > > > and have no idea on how to get it working again.
>  > > >
>  > > > I have my server, which runs Homeseer & a Redrat.
>  > > >
>  > > > The Redrat xAP program is loaded first, as this also
acts as a hub.
>  > Then
>  > > > once loaded, Homeseer with the xAP conduit is run. IR
commands are
>  > > then send
>  > > > from Homeseer to the Redrat via xAP. It's all on the
same PC.
>  > > >
>  > > > Now this normally works beautifully, but for some
reason it has
> stopped
>  > > > working. If I load on xAP viewer, I am getting NO xAP
messages at
>  > > all... not
>  > > > even a heartbeat. xAP messages sent do not get
received by
>  > > anything.. not
>  > > > Homeseer, not the RedRat, and not the viewer.
>  > > >
>  > > > The only thing I can think of that MAY have caused
this is the
>  > server IP
>  > > > address. It was recently accidentally changed to DHCP
and spend two
>  > days
>  > > > with a different IP address. I've since set it back to
static. Could
>  > > this
>  > > > somehow cause the problems?
>  > > >
>  > > > It's as if xAP is unable to loop back to the local
PC?!?!
>  > > >